53
G
B
FAULT
SOLUTION
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
Check the integrity of fuse F1. If the fuse is blown, use only a suitable replacement.
F1 = T 5A MOTOR PROTECTION FUSE
The motor opens and closes, but it has no strength and moves slowly.
Check trimmers TORQUE and LOW-SPEED adjustment.
The gate opens but does not close after the time set.
Make sure that the TCA trimmer is activated with LED DL6 ON.
B.I.O. contact always on => check the status of the clock connected to B.I.O..
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
The gate does not open or close by activating the various START, RADIO, OPEN and CLOSE
buttons.
Stop, Edge or Photocell with DIP 4 OFF contact fault => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the
photocells.
The electric lock does not work.
Ensure to have enabled DIP 8 at ON.
Check the cable.
The buzzer emits 2 long tones and the gate does not move
Safety edge with 8,2 K
Ω
resistor. Remove the resistor or configure the EDGE input via the
RIB GATE app
The remote control does not work. Led DL12 lit red
Lack of radio module in connector J5 or faulty radio module.
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
EVENT
BUZZER STATUS
FLASHER STATUS
DL1 LED STATUS
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Off
Off
Flashes on-off 250 ms
Dip 2 ON (full stroke programming)
Off
Off
Flashes on-off 500 ms
Dip 2>1 ON (pedestrian stroke programming)
Off
Off
Flashes on-off 500 ms
Programming sequence stopped due to intervention of a safety
device
10 seconds tone with 2 seconds pause
Off
On steady
EVENT
BUZZER STATUS
FLASHER STATUS
DL12 LED STATUS
No transmitter code entered
Off
Off
Flashes intermittently red/green
Dip 1 > 2 - transmitter code programming for full opening
Off
Off
Flashes red for 10 seconds
Dip 1 > 3 - transmitter code programming for pedestrian
opening
Off
Off
Flashes green for 10 seconds
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Off
Off
Flashes orange for 10 seconds
Correct transmitter codes programming for full opening and
R-AUX relay
1 Tone
Off
Turns green once
Correct transmitter codes programming for pedestrian opening
1 Tone
Off
Turns red once
Remote control code not present in memory
Off
Off
Red flash
Memory saturated by remote control codes (1000 codes saved)
Off
Off
Runs 6 green flashes
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
2 Tones
Off
Runs 2 green flashes
WARNING SIGNALS DURING OPERATION
EVENT
BUZZER STATUS
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
Stop button pressed
Off
Off
Led DL6 turns off
Photocell intervention
1 Tone
Off
Led DL7-8 turns off
Edge intervention
2 Tones
Off
Led DL9-10 turns off
Failure of a safety device or safety device engaged for too long
Off
Off
Led DL1 flashes on-off 250 ms
Running with emergency batteries (24 vdc)
Off
Currently enabled
Signal output flashes on-off twice for 250 ms
followed by a pause of 2 seconds
Alarm from edge
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Enabled for 1 minute
No led combined
Failed photocells auto-test alarm
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
No led combined
Functional block activated by smartphone
Off
Off
Led DL12 is steady on green.
Achievement of set cycles
6 Tones every 5 seconds
(It is renewed by giving a command)
Off
No leds matched
Energy saving activated by smartphone
Off
Off
Blue led flashes once every 5 seconds
Summary of Contents for IDRO C 27/1B
Page 74: ...74 ...