background image

 A3 dp 

6 Technical specifications 

12 

 

 

 

 

 

 

 

 

 

 

 

6

 

Technical specifications 

Speaker Components 

2 x 8" Nd / 1" 

Description 

HiMid Sound System 

Amp Power 

LF: 500 W AES / 110-230 V 
HF: 150 W AES / 110-230 V 

Rated Current 

 0,6 A @ 230 V 

SPL 

(Peak @ 1m)

 

132 dB 

Max. Input Signal 

25 dBu 

DSP 

HDLM FPGA Processing 32 bit floating point 

AD / DA 

24 bit / 96 kHz 

Latency 

0,8 ms (analog in to analog out) 

Usable Range 

(-6dB)

 

80 Hz - 20 kHz 

Tuning Frequency 

(excursion minimum)

 

90 Hz 

X - Overpoint

 (acoustical)

 

depends on preset 

Coverage 

(horizontal / vertical)

 

90° x 60° - rotatable 

Max. Splay Angle 

- - - 

Connectors 

Neutrik XLR in/out 

Neutrik PowerCon in/out 

Handles 

1 x 

Rigging 

(flying points)

 

4 x M10 / 2x M6 

35 mm pole mount 

Weight 

13,5 kg 

Size 

(height x width x depth)

 

59,0 x 25,0 x 25,0 cm 

Order No. 

00240/II/dp 

The  technical  data  sheet  and  further  information  about  possible  applications  for  the  system  and 

available accessories can be downloaded at the following Internet address: 

https://www.seeburg.net/download_getfile.php?file=downloads/06-Datenblaetter/A-Serie/A3-

dp_Datenblatt_dt.pdf

 

Summary of Contents for 00240/II/dp

Page 1: ...User Manual A3 dp Version 3 1 18 05 2020 ...

Page 2: ...nectors 7 4 3 Controls 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 10 5 4 1 Preset Bank 1 Default Settings 10 5 5 Reprogramming of dp speakers with preset audio files 11 5 6 Locking the buttons 11 6 Technical specifications 12 7 Declaration of conformity 13 ...

Page 3: ...imize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner individual config...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...A3 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...er approximately 3 seconds Avoid repeatedly switching the system on and off particu larly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the A3 dp under full po...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...e DSP controller in up to 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blin...

Page 10: ...et when the bot tom of the four vertical LEDs lights up 5 4 1 Preset Bank 1 Default Settings This bank contains the recommended settings for A3 dp systems fitted with the DPLM DSP controller Flat Preset for single application or in combination with a subwoofer e g G Sub 1501 dp HP Flat preset with a higher cut off frequency for the high pass filter for combination with a subwoofer The higher cut o...

Page 11: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 12: ...ursion minimum 90 Hz X Overpoint acoustical depends on preset Coverage horizontal vertical 90 x 60 rotatable Max Splay Angle Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 1 x Rigging flying points 4 x M10 2x M6 35 mm pole mount Weight 13 5 kg Size height x width x depth 59 0 x 25 0 x 25 0 cm Order No 00240 II dp The technical data sheet and further information about possible applic...

Page 13: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2018 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 14: ...ax 49 0 7307 97 00 29 www seeburg net info seeburg net Benutzerhandbuch User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change ...

Reviews: