5 Operation 

12 

 

 

 

 

 

 

 

 

 

 

 

5.5

 

Reprogramming of dp-speakers with preset audio files 

By default, the built-in DSP controller is in a default configuration state that conforms to the descrip-

tion  in the User  Manual. The installation of special presets on the DSP controller can be done  by 

the user himself, since only a special preset audio file must be loaded. The programming of these 

audio files via the LPI (Loudspeaker Programming Interface) can only be done by the manufactur-

er.  

The preset is getting installed on the DSP by playing the preset audio file in the XLR input. This can 

be done in different ways (MP3 player, smart phone, PC, CD player, ...). Installation via PC is done 

as follows: 

1.  Use  a  mini-jack-XLR  (stereo)  cable  to  connect  the  headphone  output  to  the  XLR  input  of 

the self-powered box. Use only one of the XLR connectors. 

2.  Mute the box by pressing the Set button in Status Mode. The Mute LED lights up. The DSP 

controller can only receive data in the muted state. 

3.  Make sure your computer's volume is set to 100%. 

4.  Load the ".wav" file received from SEEBURG acoustic line into a music player. 

5.  Press the play button. 

6.  After a successful programming operation, the Mute LED turns off. 

 

It  is  very  important  to  ensure  that  the  preset  audio  file  is  played  in 

single  mode.  Other  music  files  in  the  playlist  or  on  the  data  storage 

medium will otherwise be played at full volume. 

5.6

 

Locking the buttons 

 

Press  and  hold  the  Set  and  Mode  buttons  simultaneously  for  more 

than 3 seconds to lock the controls of the system. Repeat the action 

to unlock the system. 

Summary of Contents for 00550/dp/120

Page 1: ...User Manual G3 dp Version 3 2 18 05 2020 ...

Page 2: ...s 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 10 5 4 1 Preset Bank 1 Compatibility Mode 11 5 4 2 Preset Bank 2 Default Settings 11 5 5 Reprogramming of dp speakers with preset audio files 12 5 6 Locking the buttons 12 6 Technical specifications 13 7 Declaration of conformity 14 ...

Page 3: ...stics and minimize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner indi...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...G3 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...r approximately 3 seconds Avoid repeatedly switching the system on and off particular ly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the G3 dp under full pow...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...o 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blinks to indicate the first...

Page 10: ... Mode Three different presets with an each switchable Soft Mode are available in each bank for selection via the Set button The four vertically aligned LEDs indicate the current selection The Soft Mode is activated in the preset when the bot tom of the four vertical LEDs lights up Increasing the length of the line source of the G3 system results in a level addition in the low mid range and stronge...

Page 11: ...ft Mode operates in dependently of which of the three presets is selected If this mode is switched on the G3 dp is operating in Soft Mode 5 4 2 Preset Bank 2 Default Settings This bank contains the recommended settings for G3 dp systems fitted with the DPLM DSP controller Flat Preset for single application or in combination with a subwoofer e g G Sub dp and G Sub Low Preset with a level reduction ...

Page 12: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 13: ... version 80 x 20 80 version Mechanical Splay Angle 12 Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 2 x Rigging flying points 8 x M10 incl Flying Bracket Weight 43 0 kg Size height x width x depth 67 1 x 51 2 x 48 2 cm Order No 00550 dp 120 00550 dp 80 The technical data sheet and further information about possible applications for the system and available accessories can be downlo...

Page 14: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2010 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 15: ...ax 49 0 7307 97 00 29 www seeburg com info seeburg net Benutzerhandbuch User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change ...

Reviews: