background image

 G3 dp 

3 Safety instructions 

 

 

 

 

 

 

 

 

 

 

 

3

 

Safety instructions 

 

Acoustic 

Even  a  low  input  level  can  result  in  a  sound  pressure  level  at  the 

loudspeaker which can be damaging to  your hearing.  Do not remain 

in close proximity to the  loudspeaker when it  is being operated. Use 

hearing protection. Observe all relevant Health and Safety and Envi-

ronmental Protection regulations. 

 

Mechanical 

Movable  parts  and  falling  objects  during  installation  and  de-rigging 

can cause serious injury. Observe at all times all relevant Health and 

Safety regulations and regulations on the installation and operation of 

PA systems. 

 

Magnetic und electrical 

Loudspeakers  generate  a  magnetic  field  even  without  a  source  of 

power  connected.  This  can  damage  or  destroy  magnetic  storage 

devices. The PowerCon loop-through connector is under power when 

the  device  is  in  operation.  Observe  all  relevant  safety  regulations  at 

all times. 

 

General safety precautions 

The installation and de-rigging of this equipment should only be car-

ried  out  by  appropriately  qualified  and  experienced  personnel,  and 

according to all relevant safety regulations.  Find out about the appli-

cable regulations in the country  you  work in and comply  with the re-

spective regulations. 

Do  not  operate  the  loudspeaker  if  you  have  any  doubts  about  the 

safety  of  doing  so,  or  if  the  loudspeaker  shows  any  signs  of  faulty 

operation. There are no user serviceable parts inside the device. For 

repairs, contact your dealer or a qualified service technician. 

The loudspeaker is a class 1 device requiring a 230 V / 50 Hz power 

connection with earth contact. 

Summary of Contents for 00550/dp/120

Page 1: ...User Manual G3 dp Version 3 2 18 05 2020 ...

Page 2: ...s 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 10 5 4 1 Preset Bank 1 Compatibility Mode 11 5 4 2 Preset Bank 2 Default Settings 11 5 5 Reprogramming of dp speakers with preset audio files 12 5 6 Locking the buttons 12 6 Technical specifications 13 7 Declaration of conformity 14 ...

Page 3: ...stics and minimize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner indi...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...G3 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...r approximately 3 seconds Avoid repeatedly switching the system on and off particular ly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the G3 dp under full pow...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...o 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blinks to indicate the first...

Page 10: ... Mode Three different presets with an each switchable Soft Mode are available in each bank for selection via the Set button The four vertically aligned LEDs indicate the current selection The Soft Mode is activated in the preset when the bot tom of the four vertical LEDs lights up Increasing the length of the line source of the G3 system results in a level addition in the low mid range and stronge...

Page 11: ...ft Mode operates in dependently of which of the three presets is selected If this mode is switched on the G3 dp is operating in Soft Mode 5 4 2 Preset Bank 2 Default Settings This bank contains the recommended settings for G3 dp systems fitted with the DPLM DSP controller Flat Preset for single application or in combination with a subwoofer e g G Sub dp and G Sub Low Preset with a level reduction ...

Page 12: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 13: ... version 80 x 20 80 version Mechanical Splay Angle 12 Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 2 x Rigging flying points 8 x M10 incl Flying Bracket Weight 43 0 kg Size height x width x depth 67 1 x 51 2 x 48 2 cm Order No 00550 dp 120 00550 dp 80 The technical data sheet and further information about possible applications for the system and available accessories can be downlo...

Page 14: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2010 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 15: ...ax 49 0 7307 97 00 29 www seeburg com info seeburg net Benutzerhandbuch User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change ...

Reviews: