background image

 G3 dp 

6 Technical specifications 

13 

 

 

 

 

 

 

 

 

 

 

 

6

 

Technical specifications 

Speaker Components 

6 x 8" Nd / 3 x 1,4" Nd 

Description 

Curved Cylindric Wave Radiator 

Amp Power 

LF: 2400 W AES / 110-230 V 
HF: 700 W AES / 110-230 V 

Rated Current 

2,9 A @ 230 V 

SPL 

(Peak @ 1m)

 

140 dB 

Max. Input Signal 

25 dBu 

DSP 

HDLM FPGA Processing 32 bit floating point 

AD / DA 

24 bit / 96 kHz 

Latency 

0,8 ms (analog in to analog out) 

Usable Range 

(-6dB)

 

80 Hz - 18 kHz 

Tuning Frequency 

(excursion minimum)

 

90 Hz 

X - Overpoint

 (acoustical)

 

depends on preset 

Coverage 

(horizontal / vertical)

 

120° x 20° (120°-version) 
80° x 20° (80°-version) 

Mechanical Splay Angle 

12° 

Connectors 

Neutrik XLR in/out 

Neutrik PowerCon in/out 

Handles 

2 x 

Rigging 

(flying points)

 

8 x M10 
incl. Flying Bracket 

Weight 

43,0 kg 

Size 

(height x width x depth)

 

67,1 x 51,2 x 48,2 cm 

Order No. 

00550/dp/120 
00550/dp/80 

The  technical  data  sheet  and  further  information  about  possible  applications  for  the  system  and 

available accessories can be downloaded at the following Internet address: 

http://www.seeburg.net/download_getfile.php?file=downloads/06-Datenblaetter/G3/G3-

dp_Datenblatt_dt.pdf

 

 

This manual applies  only to systems fitted  with the 

DPLM

-DSP Con-

troller. 

The version fitted with the 

DPLM

-DSP Controller can be identified by 

the control panel located above the XLR connectors. 

 

Summary of Contents for 00550/dp/120

Page 1: ...User Manual G3 dp Version 3 2 18 05 2020 ...

Page 2: ...s 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 10 5 4 1 Preset Bank 1 Compatibility Mode 11 5 4 2 Preset Bank 2 Default Settings 11 5 5 Reprogramming of dp speakers with preset audio files 12 5 6 Locking the buttons 12 6 Technical specifications 13 7 Declaration of conformity 14 ...

Page 3: ...stics and minimize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner indi...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...G3 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...r approximately 3 seconds Avoid repeatedly switching the system on and off particular ly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the G3 dp under full pow...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...o 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blinks to indicate the first...

Page 10: ... Mode Three different presets with an each switchable Soft Mode are available in each bank for selection via the Set button The four vertically aligned LEDs indicate the current selection The Soft Mode is activated in the preset when the bot tom of the four vertical LEDs lights up Increasing the length of the line source of the G3 system results in a level addition in the low mid range and stronge...

Page 11: ...ft Mode operates in dependently of which of the three presets is selected If this mode is switched on the G3 dp is operating in Soft Mode 5 4 2 Preset Bank 2 Default Settings This bank contains the recommended settings for G3 dp systems fitted with the DPLM DSP controller Flat Preset for single application or in combination with a subwoofer e g G Sub dp and G Sub Low Preset with a level reduction ...

Page 12: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 13: ... version 80 x 20 80 version Mechanical Splay Angle 12 Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 2 x Rigging flying points 8 x M10 incl Flying Bracket Weight 43 0 kg Size height x width x depth 67 1 x 51 2 x 48 2 cm Order No 00550 dp 120 00550 dp 80 The technical data sheet and further information about possible applications for the system and available accessories can be downlo...

Page 14: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2010 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 15: ...ax 49 0 7307 97 00 29 www seeburg com info seeburg net Benutzerhandbuch User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change ...

Reviews: