background image

                                                                                                            

      G3 dp 

                                                                                                             SEEBURG acoustic line

 

 

 

Do not operate the G3  dp  if  you have any concerns regarding safety  or if the 

loudspeaker  box  should  malfunction.  The  equipment  has  no  user-serviceable 

parts  inside.  In  the  event  of  repair,  please  contact  your  dealer  or  qualified 

personnel respectively.  

 

Connect  the  G3  dp  to  a  115-230V/50-60Hz  grounded  safety  socket.  The 

equipment corresponds to protection class 1. In case of overload, a protective 

element is activated which reliably protects the amplifier module and the DSP. 

However, it must then be replaced by an authorised service centre.  

Always  remove  the  mains  plug  when  opening  the  loudspeaker  box  (for 

example when turning the horn).   

 

Do not expose the G3 dp  to rain and, if possible, do not operate the speaker 

outside  of  a  temperature  range  of  -5°C  to  40°C.  Bear  in  mind  that  strong 

thermal  fluctuations  result  in  the  formation  of  condensate,  therefore  do  not 

operate  the  speaker  until  the  speaker  box  has  assumed  the  ambient 

temperature.  Do  not  switch  the  equipment  off  if  it  is  being  used  in  adverse 

conditions. 

  

In  order  to  avoid  overheating  of  the  speaker  chassis  and  the  built-in  amplifier 

module, never  operate the G3 dp  in the close vicinity of intense heat sources 

and avoid direct sunlight.  

After several hours of operation the housing (especially all-metal parts such as  

the M20 flange and connection panel) can reach temperatures of up to 40°C.   

 

 

Summary of Contents for G3 dp

Page 1: ...User Manual G3 dp Last update 07 2010 ...

Page 2: ...word 3 Safety instructions 4 Part 1 Connections and indicator functions Connectors 6 Control elements 7 Status indicators 7 Part 2 Operation System start up 8 Adjusting sound levels 8 Accessing presets 9 Appendix Assembly Instructions Data sheet ...

Page 3: ...m Both ground stacked and flown applications are possible High grade electronic components from the industrial sector and a first class circuit design ensure excellent audio quality with low distortion and effectively minimise static noise Highly efficient and intelligent limiter systems ensure optimum protection against overload without restricting the possibilities offered by this high performan...

Page 4: ... principles of prevention as well as those regarding event and production facilities for the performing arts magnetic and electrical Even if not connected to a power source loudspeakers produce a static magnetic field that can damage cards with a magnetic strip or delete sound recordings and the like During operation this voltage is also present on the PowerCon Loop Thru input Observe the respecti...

Page 5: ...ains plug when opening the loudspeaker box for example when turning the horn Do not expose the G3 dp to rain and if possible do not operate the speaker outside of a temperature range of 5 C to 40 C Bear in mind that strong thermal fluctuations result in the formation of condensate therefore do not operate the speaker until the speaker box has assumed the ambient temperature Do not switch the equip...

Page 6: ...s to be supplied to several active speaker boxes and only a 115 230 Volt AC lead is being used Please observe the maximum permitted connected load In practice power can be supplied to up to two additional systems PowerCon blue Power supply 115 250 VAC This plug has the same function as an on off switch Ensure that a 115 230 VAC mains voltage is available After switching on clockwise rotation until...

Page 7: ...ors Mute LED red light when the system is muted press Set button in Status mode or under technically crucial conditions Limit LED yellow light when the limiter is restricting the level of at least one amplifier channel Signal LED green light if a signal exceeds 20 dBU This also applies when the mute function has been activated Power LED lights up when the system is switched on ...

Page 8: ...essed once the mute function is deactivated the Mute LED goes off and the system transmits a signal Adjusting sound levels By pressing the Mode button once you will gain access to the Level mode permitting adjustment of the volume in 3dB stages Four different values 3dB 0 dB standard 3dB and 6 dB are available Adjustment is effect via the SET button The green LED located above it indicates which m...

Page 9: ...ion taking place when several G3 dp are operated in a line Low hard The low mids are reduced even mor for better speech intelligibility Stronger reduction of the low mid summation taking place when several G3 dp are operated in a line Soft Mode Lowers the level within the frequency range of 2 5 5 kHz which is sensitive to the ear This setting is recommended for high level reproduction of highly co...