K Sub 1502 dp
4 Connectors/Indicators
7
4.2
Connectors
XLR connectors (1)
The K Sub 1502 dp should be connected with a standard symmetrically wired XLR cable. To con-
nect the input signal to further devices, use the male XLR Loop thru connector. To obtain full power
performance from the system, the signal source should be able to provide a minimum of 6 dBu
distortion free output voltage.
PowerCon blue (2)
Power supply input voltage 110-230 VAC. This connector provides the function of an on-off switch.
After powering on (turn the connector to the right until it locks), the systems starts up and is ready
for use after approximately 3 seconds. Avoid repeatedly switching the system on and off, particu-
larly when it is operating.
PowerCon grey (3)
110-230 VAC loop-through connector. This connector is to be used when multiple active loud-
speakers are to be provided with power from one source. Please observe carefully the maximum
power capacity of the power source.
The nominal power consumption of the K Sub 1502 dp under full
power is 3.2 A (measured with pink noise, Crest Factor 8). Transient
peaks can, however, cause much higher momentary power drain.
Observe carefully the nominal power consumption when connecting
the loudspeaker(s) to the power source, and observe carefully the
cut-off current of the safety circuit breakers. We recommend using the
loudspeaker on power circuits with circuit breakers with C characteris-
tic.