background image

                                                                                                            

      TSM Sub dp+ 

                                                                                                             SEEBURG acoustic line

 

 

 

 

 

 

 

Control elements 

 

 

MODE 

button: changing to control modes Status / Level and Presets. 

 

SET 

button:  Setting of various values and Mute on/off 

 

 

 

 

 

Status indicators 

 

 

Mute  LED

:  red  light  when  the  system  is  muted  (press  Set  button  in 

Status mode) or under technically crucial conditions.  

 

Limit  LED:

  yellow  light  when  the  limiter  is  restricting  the  level  of  at 

least one amplifier channel.   

 

Signal LED:

 green light if a signal exceeds –20 dBU. This also applies 

when the mute function has been activated:   

 

Power LED: 

lights up when the system is switched on.  

 

 

Summary of Contents for TSM Sub dp+

Page 1: ...User Manual TSM Sub dp Last update 01 2009 ...

Page 2: ...ic line 2 Contents Foreword 3 Safety instructions 4 Part 1 Connections and indicator functions Connectors 5 Control elements 6 Status indicators 6 Part 2 Operation System start up 7 Adjusting sound levels 7 Accessing presets 8 ...

Page 3: ...configured presets and volume settings can be selected High grade electronic components from the industrial sector and a first class circuit design ensure excellent audio quality with low distortion and effectively minimise static noise Highly efficient and intelligent limiter systems ensure optimum protection against overload without restricting the possibilities offered by this high performance ...

Page 4: ...Never open the equipment as there are no user serviceable parts inside Do not expose TSM Sub dp to rain and if possible do not operate the speaker outside of a temperature range of 5 C to 40 C Bear in mind that strong thermal fluctuations result in the formation of condensate therefore do not operate the speaker until the speaker box has assumed the ambient temperature Do not switch the equipment ...

Page 5: ...In this case the slide switch on the TSM Sub must be set to the BiAmp position 2 2 PowerCon grey 230 VAC Loop Thru input This is required if power is to be supplied to several active speaker boxes and only a 230 Volt AC lead is being used Please observe the maximum permitted connected load In practice power can be supplied to up to two additional systems PowerCon blue Power supply 195 250 VAC This...

Page 6: ...ators Mute LED red light when the system is muted press Set button in Status mode or under technically crucial conditions Limit LED yellow light when the limiter is restricting the level of at least one amplifier channel Signal LED green light if a signal exceeds 20 dBU This also applies when the mute function has been activated Power LED lights up when the system is switched on ...

Page 7: ...pressed once the mute function is deactivated the Mute LED goes off and the system transmits a signal Adjusting sound levels By pressing the Mode button once you will gain access to the Level mode permitting adjustment of the volume in 3dB stages Four different values 3dB 0 dB standard 3dB and 6 dB are available Adjustment is effect via the SET button The green LED located above it indicates which...

Page 8: ...bination of at least 2 subwoofers can be substantially increased When the cardioid mode is activated the TSM Sub dp should be placed in a position that allows the sound to be directed to the rear whilst a second subwoofer active or passive directs the sound to the front Special circuitry produces directional kidney shaped cardioid sound characteristics The best effect is achieved if the TSM Sub dp...

Page 9: ......

Page 10: ......

Reviews: