Seedburo Equipment Company | 9000AG Manual Revision 1.0
10
Parameters in order of occurrence (
BOLD
values are the defaults):
Percent Calculation Parameter
PCr
Percent mode defines the way the Dockage is displayed.
SPt
Standard
– Displays a percent value based on the formula current weight divided
by memory value. example 200g/2000g=10% dockage
rPt
Reciprocal
– Displays percent value based on (memory weight- current weight) divided
by memory weight. example (2000g-200g)/2000g=90% good product
Percent Mode Parameter
PCd
Percent mode defines the method of how the % calculation is displayed
ACt
Active mode continuously updates the display
Frn
Frozen mode calculates the % only when the % switch is pressed.
SAVE Parameter:
SAVE
SAVE mode
allows the user to permanently save the changes made to the parameters
N
Do not exit and Save. Continue to next parameter.
Y
Exit Setup mode and SAVE changes. The scale will return to the weighing mode once
the
g
switch is pressed.
Default Scale to factory parameter settings:
dft
Default scale parameters
N
Do not default parameters. Continue to next parameter.
Y
Default Parameters to factory defaults. All default values are in BOLD text.
Analog to Digital Counts:
xxxxxx
Displays Analog to Digital Data
Press g to exit raw counts
Load Cell mv output:
xxxxxx
Displays Internal Load Cell voltage
Press g to exit voltage reading