Seedburo Equipment Company | 9000AG Manual Revision 1.0
12
Section 7
Printer Modes:
The Model 8800SS offers four different print control modes. These modes dictate when
printer data is sent.
Transmit on demand (
tod
):
In this mode, scale data is transmitted whenever the
button is pressed, or a print
request is received from the serial port. The scale must be stable and the scale value
must be valid before the data is printed.
Continuous print (
CP
):
In continuous print, data is transmitted each time the scale has a reading ready.
Readings which occur when the scale is in motion are called out by the abbreviation
"MOT." following the data.
Auto Print 1 (
AP1
):
Auto Print 1 transmits the first scale reading after the scale leaves motion. The reading
must be stable and must be a valid reading before it can be sent.
Auto Print 2 (
AP2
):
Like Auto Print 1, Auto Print 2 transmits the first scale reading following the scale
leaving motion. In Auto Print 2, no further readings will be sent until the scale returns to
displayed zero. The reading must be stable and must be a valid reading before it can be