Seedburo Equipment Company | 9000AG Manual Revision 1.0
8
Section 5
Parameters in order of occurrence (
BOLD
values are the defaults):
Calibration Parameter
CAL
Zero Calibration Mode
0
Press
ZERO
switch on user interface to perform the Zero calibration of the scale. Display
will count down and automatically go to
CAL FS
unless an error occurs.
Note
: The CAL 0 function will automatically adjust the offset and gain to
compensate for dead load and span. The scale must be level and on a solid surface.
Excessive vibration and/or wind may cause the scale not to be able to perform this function.
CAL
Span Calibration Mode
Will only appear upon successful completion of the CAL 0 function above.
FS
Set 2,000 grams on the platter. Press
ZERO
switch on user interface to perform the
SPAN calibration of the scale. Display will count down and automatically go to
operating
mode
unless an error occurs.
Digital Filter Parameter:
Avg
Averaging mode
calculates the number of samples to average before displaying a
weight. Display updates 10 times per second.
0
1 reading. No Average in this mode.
1
Circular Auto averaging, 1 reading averaged
2
Circular Auto averaging, 2 readings averaged
4
Circular Auto averaging, 4 readings averaged
8
Circular Auto averaging, 8 readings averaged
16
Circular Auto averaging, 16 readings averaged
Auto Zero Tracking:
AZt
Automatic Zero Tracking Range
Small weights within the specified number of divisions are automatically zeroed.
oFF
Zero tracking is off.
0.5
Zero tracking to within 0.5 divisions.
1.0*
Zero tracking to within 1.0 divisions.
2.0*
Zero tracking to within 2.0 divisions.
3.0*
Zero tracking to within 3.0 divisions.
Auto Zero Tracking:
mmA*
Motion Aperature *
Determines how many divisions consecutive readings must change before the scale is
considered in motion. (Stable LED will turn off when in motion)
1
1 division change will cause the scale to enter into motion
2
2 division change will cause the scale to enter into motion
3
3 division change will cause the scale to enter into motion
5
5 division change will cause the scale to enter into motion
*Note
: The Legal for Trade modes(
Op
parameter equals
44
or
CAn
) will disable the * values.