background image

-19- 

12A4A2-00007E-8 

 

10.  Others 

For comments or queries, feel free to contact us via e-mail or phone. 

 

 

 

By Phone 

  +1-630-832-0438 (Business Hours: 9:00a.m. ~5:45p.m. CT) 

 

By E-mail 

sales@uscoamerica.com 

 

FAQ 

       

www.seedsware.co.jp/global/support/faq/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Microsoft®,  Windows®  Embedded  Compact7,  Windows  Mobile  Device  Center®,  Visual  Studio.NET  2008®,  are 

registered trademarks of Microsoft Corporation in the United States and other countries. 

8

th

  Edition  October,  2016 

USCO America Inc. 

136  W.  Valletts  Street,  Elmhurst,  IL  60126  USA 

Phone: 630-832-0438/510-931-9046 

E-mail:  sales@uscoamerica.com 

Business hours: 9:00a.m.

5:45p.m. (Central Time) 

http://uscoamerica.com/ 

This document is protected by copyright law. Photocopying, duplicating, reproducing, and modifying of this product or 

document in part or by whole is prohibited. 

 

Summary of Contents for EMG Series

Page 1: ... CE Embedded Panel Computer EMG7 Model EMG7 W207A8 0024 x11 01 Product Specification Seedsware Corporation http www seedsware co jp global Contents in this document may change without prior notice Please obtain the delivery specification for the latest design ...

Page 2: ...rial Port COM 1 9 4 8 3 Ethernet 9 4 8 4 USB Host Port 10 4 8 5 USB Device Port 10 4 8 6 Audio Interface LINE OUT 11 4 8 7 Audio Interface MIC IN 11 4 8 8 Power Connector 11 4 9 Software Specification 12 4 9 1 Application Software Development Environment 12 5 Installation 13 5 1 Installing Condition 13 5 2 Mounting 14 5 2 1 Panel Mounting 14 5 2 2 Mounting to a VESA Arm 15 6 Compatible Standards 1...

Page 3: ...omputer with Indusoft EMG7 W207A8 0024 111 01 3 Packaged Contents The following items are included in the package EMG7 1 unit Mounting Bracket IS TK 01 1 set 4 pcs Battery SWBT 01 1 pc Protective Sheet SWCA 7WS00 001 1 pc Gasket SWPK 7W 01 1 pc Pre installed to unit Power Connector SWCN 01 03 1 pc Serial Port Connector SWCN 01 05 1 pc Installation Guide 2 pcs 1 English version and 1 Japanese versi...

Page 4: ...JACK MIC Input x 1 φ3 5 JACK Buzzer On board Buzzer RTC 4 RTC with a battery backup Error at the time of backup 65 seconds month Conditions ambient temperature 25 1 Does not guarantee accurate operation for all SD memory cards available in the market 2 Does not guarantee accurate function for all USB devices available in the market 3 Can only be used for connecting with Microsoft Windows Mobile De...

Page 5: ...stics In order to use it correctly preform calibration for sensitivity sensor of touch screen when building into a device Also if at any time the touch screen operations become unstable due to changes in the setting environment or installation perform sensitivity sensor calibration If there is moisture on the touch screen surface it may not operate properly When moisture is detected on the surface...

Page 6: ...ructure Protection Structure IP65 1 Front side only when mounted to panel Installation Panel mounting Cooling Natural cooling Weight Approx 700g unit only External Dimensions 192 W mm x 137 H mm x 36 D mm Panel Cutout Dimensions 183 5 0 5 0 W mm x 128 5 0 5 0 H mm 1 Protection structure of the front part of the unit when installed to a panel Although it has been tested under conditions equivalent ...

Page 7: ...lays the state of the EMG by the LED color shown below LED State EMG State Off Power not applied Amber steady OS starting Green steady Normal operating state Green blinking Backlight off Normal Operation 4 7 2 Back B Battery cover C License label D Product label E FCC label A B C D E ...

Page 8: ...3 Right F SD Card Slot G USB Device H Audio Interface LINE OUT I Audio Interface MIC IN 4 7 4 Top J Mounting Holes 4 7 5 Bottom K Power Input L Ethernet M USB Host N Serial Port COM1 O Mounting Holes F G H I J J K L n M N O O ...

Page 9: ...connector Tyco Electronics 284539 5 Recommended cable connector SWCN 01 05 Tyco Electronics 284510 5 Included as accessory PIN No Signal Schematic 1 TXD 2 RXD 3 RTS 4 CTS 5 SG 4 8 3 Ethernet Ethernet 10BASE T 100BASE TX Connector RJ 45 PIN No Signal Schematic 1 TX 2 TX 3 RX 4 NC 1 5 NC 1 6 RX 7 NC 1 8 NC 1 1 NC is not connected Status LED LED State State On Green LINK ACT On Yellow SPEED Compatibl...

Page 10: ...nector Type A connector Maximum supply current 0 5A Port PIN No Signal All ports common Schematic 1 USB_VCC 2 D 3 D 4 SG 4 8 5 USB Device Port Interface USB2 0 Connector Type B Mini connector PIN No Signal Schematic 1 USB_VCC 2 D 3 D 4 NC 1 5 SG 1 NC is not connected 1 5 1 4 1 4 ...

Page 11: ...Lineout L 4 8 7 Audio Interface MIC IN Interface MIC IN Mono Connector φ3 5 Stereo JACK Maximum input level 250mVrms PIN No Signal Schematic 1 SG 2 NC 1 3 MIC 1 NC is not connected 4 8 8 Power Connector Interface 24VDC IN Connector Euro terminal connector Tyco Electronics 284510 3 Recommended cable connector SWCN 01 03 Tyco Electronics 284510 3 Included as accessory PIN No Signal Schematic 1 FG 2 ...

Page 12: ...t of Microsoft 4 9 1 Application Software Development Environment Below tools can be used for application software development Microsoft Visual Studio NET 2008 1 1 SDK provided must be built into above listed tools when developing applications Microsoft Windows Mobile Device Center can be used with USB device port of EMG7 USB client can be can be used as communication port ...

Page 13: ...ss are within their designated ranges Ambient operation temperature indicates both the display side and inside of cabinet where the EMG7 will be installed EMG7 should be mounted perpendicular but if it should be mounted in an angle the angle shall not be more than 30degrees from the vertical position shown in the illustration below When installing the EMG7 in a slanted panel of angle 30 degrees or...

Page 14: ...l please use the metal Be recommended panel thickness range depending on material and size may not maintain the strength when an impact is applied Please do take into account such as reinforcement in the environment impact such as join There is a possibility of personal injury or product damage when dropped product Please be careful not to drop 0 0 5 183 5 128 5 0 0 5 4 R3以 下 Under 4 R3 ...

Page 15: ...andards Association VESA MIS D arm stand or apparatus that is listed to comply with the UL1678 standard Refer to manual of arm or stand for installation procedures Mounting hole dimension is as below Use M4 screws to mount The tightening torque range is 0 7 to 0 8Nm M4 screws used should be 6mm or less in length 75mm ...

Page 16: ...ply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfer...

Page 17: ...iption IS TK 01 4pcs Gasket Model Description SWPK 7W 01 1 pc Protection sheet Model Description SWCA 7WS00 001 Package of 3pcs Batteries Model Description SWBT 01 1 pc Connector Model Description SWCN 01 03 Power connector 3Pin 1 pcs SWCN 01 05 Serial COM1 5Pin 1 pcs ...

Page 18: ...unctions and damages caused by static electricity 4 If the product is used under any condition in any environment or by any method other than those specified in the specifications catalogs manuals notes and or other documents 5 Any replacement of consumables 6 Any malfunctions defects and or damages caused by associated equipment and or usage of inappropriate consumables and media 7 If the product...

Page 19: ...Center Visual Studio NET 2008 are registered trademarks of Microsoft Corporation in the United States and other countries 8 th Edition October 2016 USCO America Inc 136 W Valletts Street Elmhurst IL 60126 USA Phone 630 832 0438 510 931 9046 E mail sales uscoamerica com Business hours 9 00a m 5 45p m Central Time http uscoamerica com This document is protected by copyright law Photocopying duplicat...

Page 20: ...ons panel opening dimension shall strictly be as specified Be sure to use installation panels without warpage scratches and dents 192 2 137 2 4 5 36 2 75 128 75 183 4 M4 ネジ侵入深さ6mm以下 Effective Screw Depth 6mm FCCラベル FCC Label 製品銘板シール Product Label 寸法許容差 TOLERANCE 呼び寸法 Nominal Dimensions L 3 10 L 18 18 L 30 6 L 10 30 L 50 0 4 0 58 0 7 0 84 1 0 0 48 3 L 6 50 L 80 80 L 120 120 L 180 180 L 250 250 L ...

Reviews: