Guardian Field Support Manual – Section 2
52
Note:
If the systems LED light turns off as soon as the ignition is turned off, then the ignition
and battery wires may have been installed incorrectly. You will have to swap the wires.
Incorrect power connection can result in a delay in the event data registering to the database
and/or ungraceful shutdown which impacts on the system operation.
Please refer to the Knowledge Base on how to install vehicles with a ‘non-essentials’ switch.
Important Points to Note:
Ensure the vehicle is isolated before performing the power connection
The Guardian fuses are to be placed before any other fuses at the fuse box, or as a fuse in the
fuse box, if spares are available. This ensures there is no extra load from other 3
rd
party devices
which may blow a fuse before Guardian’s fuse.
The Guardian fuses must also be wired after the Isolation/Non Essentials switch, if installed.
Summary of Contents for G2-SY-CON2
Page 1: ...FIELD SUPPORT MANUAL Guardian Generation 2 Gen2 ...
Page 7: ...FIELD SUPPORT MANUAL Section 1 Introduction to Guardian Generation 2 ...
Page 29: ...1 FIELD SUPPORT MANUAL Section 2 Installation of Guardian Generation 2 ...
Page 100: ...Guardian Field Support Manual Section 2 72 ...
Page 103: ...Guardian Field Support Manual Section 2 75 The vehicle can be turned off ...