MOBILEMAX ASSEMBLY MANUAL
|
11
CONVERSION INSTRUCTIONS
WIRING THE MAINS POWER
A small junction box and terminal strip is provided in the
MobileMAX Tank kit to make the connection between the
external 6.0m mains lead and the cable with the IEC plug
that plugs into the CPMD control box.
Mount the junction box on the scroll of the cooler, in close
proximity to the CPMD control box.
ILL2935-A
Drill 2 holes to suit the 16mm glands provided in the
MobileMAX Tank kit at either end of the junction box and
fit the glands.
Pass the bare end of the external 6.0m mains lead
through the gland to enter the encloure.
Mount the terminal strip inside the enclosure using at
least 1 screw.
Wire the 3 leads to one side of the terminal strip.
From the cooler packout kit, locate the 3.5m lead with an
IEC plug at one end.
Pass the bare end through the cable gland and wire the 3
leads to the other side of the terminal strip.
ILL2768-A
Ensure the Earth (Ground), Active (Hot) and Neutral
(Common) conductors from both cables are aligned
correctly onto the terminal strip.
ILL2768-A
ILL1898-B
Plug the IEC Plug into the “A” socket on the underside of
the CPMD Control box.
ILL2935-A
ILL1016-A
Ensure the IEC plug is firmly located inside the
socket.
Any excess wiring should be neatly stored above the
scroll using the small cable tie supplied.
Avoid coiling this cable!