Drain Delay Time
Display Number
00
01
02
03
04
4 hours
1 Day
2 Days
3 Days
4 Days
STANDARD
DRAIN VALVE AND BLEED SYSTEM
AUTOMATIC DRAIN VALVE
TIMER
POWER
When the air cooler is not operated for 72
hours, the drain valve will open automatically
to empty all water from the cooler. If
necessary, you can adjust this delay time with
the following steps.
1. When the cooler is off, press and hold
.
2. While still pressing
, press
.
3. A number will display indicating the
current water drain delay time according to
the table.
Press
or
to select your desired delay
time.
4.Press
to set your selection.
At any time when the wall control is OFF, you
can drain the cooler by pressing and holding
and
for 1 second. The display will
show “dr” to confirm the operation has
activated.
ALTERNATIVE BLEED SYSTEM
During operation, the bleed system will drain
small amounts of water. This ensures fresh
water is continually added to dilute salt
accumulation in the water caused through
evaporation. This helps keep the air cooler in
good condition and ensure optimum
performance. The bleed rate will depend on
local operating conditions and will be set by
the installer.
s
s
s
t
s
t
MAINTENANCE
Draining water from your air cooler at the
end of the summer season is not required if
your cooler is fitted with an automatic drain
valve. However, it is advisable to check the
pump, drain valve, solenoid and fan motor
every 2 years. If the alternative bleed
system is installed then maintenance
should be conducted before and after the
summer season as outlined below.
WARNING: We recommend maintenance is
carried out by an authorised service agent.
Climbing onto the roof is hazardous and
can result in personal injury or property
damage. Power to the cooler must be
disconnected before pad frames are
removed or you may risk personal injury.
Note that some regulating authorities
require services to be conducted at specific
intervals.
• Turn off the power supply to the cooler.
• Turn off the water supply to the cooler.
• Remove the pad frames as shown.
• A. Turn off the power switch inside the
cooler.
• B. Check and clean the lid water channels
• C. If fitted, first unclip and then remove the
bleed system as shown. Allow the tank
water to drain. Do not re-fit the bleed
system at the end of the season. Do not to
lose the o-ring.
• Thoroughly clean the tank and pump filter.
• Re-fit the pad frames.
HEALTH REGULATIONS
END OF SEASON SERVICE
A
B
C
8
SEELEY INTERNATIONAL –
OWNER’S MANUAL
9
®
TBA Evaporative Cooler