Page 9.21
9.0 Maintenance
Maintenance for 548.10 G \ 05.2007 \
Caution, Danger for your life
In the system there are some parts with mains power. By
mainte nance and ser vice pro ce du res turn the entire
system off, shut off from mains by re mo ving the mains
plug. There is danger for your life.
Danger of burns
Start working after the system is cooled down.
1.
Turn the entired system off, shut off from mains by
removing the mains plug.
2.
Unscrew the two screws of the power input on the
rear side of the system.
3.
Remove the plate.
4.
Dismount the complete grid belt transport system
descripted in the section "Dismounting and Mounting
of the grid belt transport system".
5.
Unscrew and remove the four screws of the cover
from the mains
fi
lter and take up the cover.
6.
Unscrew and remove the power input and power out-
put cable.
7.
Unscrew and remove the four screws of the mains
fi
lter and take it up.
8.
Change the mains
fi
lter against a new one.
9.
Fixe the mains
fi
lter with the four screws.
10.
Fixe the four screws of the mains
fi
lter.
11.
Fix the cover of the mains
fi
lter with the four screws.
12.
Mount the complete grid belt transport system de-
scripted in the section "Dismounting and Mounting of
the grid belt transport system".
13.
Connect the unit to the power supply again and
switch it on.
Dismounting and
mounting of the
mains
fi
lter
Summary of Contents for 548.10