Page 5.3
5.0 Operation of System
Operation of System for 548.10 G \ 05.2007 \
Technical description
The Soldering Sys-
tem
The soldering system is designed as an table system. Operati-
on and programming are conducted centrally via the operating
panel. The operating panel is including an function-key-block. All
pa ra me ters are dis play ed on the LCD.
In case of emer gen cy, the system can be shut off com ple te ly
with the main switch. The system status is displayed at the LCD.
If the systems cover will be opend during the operation an
acoustical signal sounds, the heaters and the blower will be shut
off. The complete system control is arranged on the rear side of
the system.
The heating chamber includes 3 zones. The preheating zone,
the plateau zone and the peak zone.
The temperature of the air, the value of the IR radiator and the
con veyor speed are free ad ju sta ble. Temperature sensors in the
heating chamber is measuring the tem pe ra ture for a con ti nious ly
regulation. The re gu la ti on of the con veyor speed will be done
depending on a variance com pa ri son. After the heating cham ber
a cooling zone for a gently coo ling down of the PCBs is moun-
ted.
Operating panel
Feeding Heating Cooling Discharging
zone chamber zone zone