22
M731400M00
Specification
General Specifications
Display :
6000 counts updates 1.5/sec.
Polarity Indication :
Automatic, positive implied, negative
indicated.
Overrange Indication :
“OL” or “-OL”
Low Battery Indication :
“
<
” is displayed when the battery
voltage drops below operating voltage.
Auto Power Off :
Approx 10 minutes.
Operating Ambient :
Non-condensing
≦
10°C,11°C ~ 30°C (
≦
80% R.H)
31°C ~ 40°C (
≦
75% R.H), 41°C ~ 50°C (
≦
45% R.H),
Storage Temperature :
-20ºC to 60ºC , 0 to 80% R.H. when
battery removed from Meter.
Temperature Coefficient :
0.15 x (Spec.Acc’y) / ºC , <18ºC or > 28ºC
.
Power Requirements :
Standard 9V battery NEDA 1604, IEC6F22, JIS006P
Battery Life :
Alkaline 300 hours.
Dimensions (W x H x D) :
76mm x 158mm x 38mm , without holster.
82mm x 164mm x 44mm , with holster.
Accessories :
Battery (installed), Test leads and User
manual.