TROUBLESHOOTING
11
69
Does not accept input in
from the Reset Button
unit.
Faulty connector or connections.
Check the connections between the I/O
Board, the Cabinet and the Reset Button
Unit
Faulty Microswitch
Replace Microswitch
Failure of the network
play.
Network play is wrongly set.
Reset correctly.
Communication cables are
disconnected.
Communication cables are wrongly
connected.
Reconnect the cables.
Damage of communication cables.
Replace the cables. Contact the company
from whom the unit was purchased.
Touch Screen not
responding
Clean the sceen.
Refer to chapet 10/
Faulty connections..
Check USB connections at PC and
Display sceen
Faulty USB cable
Change USB cable A/B Type
Sound is not emitted.
Sound volume adjustment is not
correct
Adjust the Switch Unit’s sound
adjustment volume.
Faulty connections for various
connectors
Check the connections for the game
board, amp, speakers and Volume
connectors
Malfunctioning BD, amp and speaker
Perform Sound Test.
Sounds are emitted and
the lamps are lit, but the
screen is black.
Faulty connections for the visual
signal connector or the monitor power
connector
Check the connections for the monitor
and game board connectors.
Faulty LCD Display
Check video output to Display using
another screen or opposing cabinet.
Colors on the monitor
screen are strange.
Faulty connection for the visual signal
connector.
Check the visual signal connector
connection and make sure it is secured
properly.
Screen adjustment is not appropriate.
Make adjustment appropriately.
The on-screen image
sways and/or shrinks.
The power source and voltage are no
correct.
Make sure that the power supply and
voltage are correct.
Does not accept input
from any switch or
volume.
Faulty connector connections.
Check the connection for the I/O Board
and Cabinet connector.
Check the power for the I/O Board.
If a problem occurs, first check to make sure that the wiring connectors are properly connected.
11 TABLE 01
PROBLEM
CAUSE
COUNTERMEASURES
When the main SW is
turned ON, the machine
is not activated.
The power is not ON.
Firmly insert the plug into the outlet.
Incorrect power source/voltage.
Make sure that the power supply/voltage
are correct.
The Fuse on the AC Unit has blown
due to momentary over current.
After eliminating the cause of overload,
replace the specified rating fuse.
The fuse of the distribtion board
has blown due to momentary over
current.
After eliminating the cause of overload,
replace the specified rating fuse.
Cabinet colours
incorrectly sequenced
Connector connection fault.
Check connections to the LED strips.
LED strip fault
Replace LED strip.