Section 6: Troubleshooting Guide
Bambi Bucket Service Manual
– Models 6072-1821 19
Section 6: Troubleshooting Guide
Valve Troubleshooting
Leaking Dump Valve
1.
Check that the bolts securing the valve and gasket to
the shell are equally fastened. There should be
approximately 2 threads exposed past each nut. If
necessary, butyl rubber sealant can be used to seal
stubborn leaks between the shell and the gasket.
2.
Work out any creases in the foam lips of the dump valve. If there is significant deterioration
in the material, it may be necessary to replace the dump valve.
3.
Check that the purse strings are tied to the ring at the
location marked on the string, and that they are
threaded through the valve grommets in an alternating
pattern.