Section 5: Using Accessories
Bambi Bucket Operations Manual 17
Once a fill has been started, the bucket will need to be supported by maintaining some tension on the
suspension lines, particularly when the bucket is nearly full. If the bucket is not supported, the flexible
nature of the bucket shell may allow it to collapse to one side as the water load increases.
Bambi
Model
Optimal
Fill Time
BB1821
30s
BB2024
34s
BB2226
37s
BB2732
45s
BB3542
59s
BB420B
59s
BB4453
75s
If operating PowerFill in extremely dirty or swampy water sources, more frequent inspections of the
pump impeller and screen may be required to maintain optimal function. The pump can be run dry
without damage.