Output Module –A
The –A version output module contains two individually fused TYCO/AMP Mat-N-
Lok
connectors.
Mating Connector: 1-480698-0
Mating Pin:
350873-3
Wire Gauge:
14-18 AWG
Fuse:
GMT-15A, Cooper Bussmann or Equivalent.
Note: The fuse is sized to provide full output power from each connection. If multiple
connections are used, the fuse can be re-sized to limit current at a lower value.
+48V RTN
+48V
FUSE 1
FUSE 2
OUTPUT MODULE –A
Layout and Polarity