background image

Version No. 1-2 - 04.06.2021

Doc. No. 9942691001

17 / 17

17. Parts supplied / Spare parts / Accessories

1 x Control cabinet air conditioner
1 x CE Declaration of Conformity
1 x Instruction manual
1 x 2800 mm Unit seals 10 x 3 mm
6 x Slotted Studs M6 * 25
6 x Washers A6,4 DIN125
6 x Lock nuts M6 DIN985
6 x Mounting Clip
1 x Drain socket
1 x O ring
2 x Drain pipes
1 x Jubilee Clip
1 x Cable tie
1 x Connection terminal

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems AG

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems Inc.

Seifert Systems Pty Ltd.

Albert-Einstein-Str. 3

HF09/10 

Wilerstrasse 16

Bärnthal 1

Rep. Office

75 Circuit Drive

105 Lewis Road

 

Hal-Far Industrial Estate

 

 

 

North Kingstown

Wantirna South

42477 Radevormwald

Birzebbuga, BBG 3000

4563 Gerlafingen

4901 Ottnang

26100 Cremona

RI 02852

3152 Victoria

Germany

Malta

Switzerland

Austria

Italy

USA

Australia

Tel.+49 2195 68994-0

Tel.+356 2220 7000

Tel.+41 32 675 35 51

Tel.+43 7676 20712 0

Tel.+39 349 259 4524

Tel.+1 401-294-6960

Tel.+61 3 98 01 19 06

info.de@seifertsystems.com info@seifertsystems.com info.ch@seifertsystems.com info.at@seifertsystem.com info@seifertsystems.com info.us@seifertsystems.com info@seifertsystems.com.au

Summary of Contents for 42691001

Page 1: ...3 4 Settings 4 5 Functional Principle 4 6 Technical Data 5 7 Mounting 6 8 Condensate management 8 9 Mounting Principle 9 10 Electrical Connection 10 11 Wiring Diagram 12 12 Taking into Operation 13 13...

Page 2: ...ons in the instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage...

Page 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...

Page 4: ...vironmental ratings please refer to the type plate data 5 Functional Principle The cooling unit for enclosures works on the basis of a refrigeration circuit consisting of four main components compress...

Page 5: ...low Volume System Unimpeded Ambient air circuit 250 650 m h Cabinet air circuit 125 250 m h Mounting Wall mounted Recessed Housing Material Mild steel powder coated Dimension A x B x C D E 600 x 320 x...

Page 6: ...irit level that the cabinet is in a horizontal position The max deviation from the vertical or horizontal is 3 degrees Air apertures To provide adequate air circulation and avoid temperature layers fr...

Page 7: ...the surface of the cabinet and remove the mounting template Stick the self adhesive unit seals on the outer surface of the cabinet for externally mounting and on the inner surface of the cabinet for...

Page 8: ...The condensation drain pipe should be attached as required e g in conditions of high humidity To install an oel cleaning drain 2 pipe please follow below steps Remove the plastic stopper from in the b...

Page 9: ...4 06 2021 Doc No 9942691001 9 17 9 Mounting Principle Do not use within the rst 15 minutes after installation 1 Mounting gasket 2 Mounting clip 3 M6 slotted set screw 4 Washer 5 Lock nut Fig 1 Recesse...

Page 10: ...external components it must be ensured that the wiring and connections are double insulated and safe against touch and protected from unauthorized and or accidental external contact Ensure that the co...

Page 11: ...minals T1 T2 Connect the door contact switch to terminals T1 T2 The contact must be closed when the cabinet door is closed SCCR Refer to UL508A Supplement SB and Seifert Systems document Short Circuit...

Page 12: ...Version No 1 2 04 06 2021 Doc No 9942691001 12 17 11 Wiring Diagram...

Page 13: ...on the PC board slightly to the right higher or to the left lower Close the unit in the prescribed manner Check that the new adjusted values meet the necessary requirements If necessary repeat the pr...

Page 14: ...Install the unit at a di erent place The ambient temperature must be within the stated operating temperature range The control cabinet is not sealed properly The control cabinet needs re sealing Fan o...

Page 15: ...ction The connections 1 2 and 3 4 are not low voltage 50V Regularly check the condenser pro le for dirt tests approx every 2 000 hours depending on the grade of ambient pollution Should the condenser...

Page 16: ...fan xing screws Connect the fan cable to the PC board and replace the board if necessary Dispose the old fan according to the environmental laws and regulations 16 Transport Storage Malfunction due t...

Page 17: ...rt Systems Ltd Seifert Systems Inc Seifert Systems Pty Ltd Albert Einstein Str 3 HF09 10 Wilerstrasse 16 B rnthal 1 Rep O ce 75 Circuit Drive 105 Lewis Road Hal Far Industrial Estate North Kingstown W...

Reviews: