2-104
(3) When the current temperature of the afterheater, print heater, and the preheater
reaches the temperature that is 1°C lower than the set temperature, the printer starts
printing.
When the current temperature is higher than the set temperature, the printer
starts printing before the temperature lowers. The temperature control is
performed continuously after printing starts because these heaters keep their set
temperature.
(4) The heater temperature varies during printing by changing the set temperature
with the heater control menu. Even after printing is completed, the set temperature
changed in the heater control menu remains as "set temperature." However, the initial
temperature value of each heater stored in MEDIA REG MENU remains unchanged.
(5) The subsequent printing returns to (2).
The three heaters work in the state displayed on the LCD regardless of the means to set
their temperatures.
The following figure shows the heater temperature control system for printing. The
standby time can be changed with the heater menu in the offline mode. (
P.3-62 [Heater
menu])
–
–
Print heater set temperature
Preheater set temperature
Afterheater set temperature
Standby set temperature
Ambient temperature
Standby time
(Time)
(Temperature)
Set temperature
maintained
Standby temperature
maintained
Temperature
control stop