35
(6)
A message for selecting the setting value of the selected function is printed as a sample shown in
Press the FEED Switch the number of times corresponding to the selected setting value number,
and then press the POWER Switch.
・
When pressing the FEED Switch once, "1 : ESC/POS" is selected.
Figure 11-4 Setting Value Selection Message
(Example: Selected Command System)
(7)
A message for confirming the selected setting value is printed as a sample shown in Figure 11-5.
Figure 11-5 Setting Value Confirmation Message
(Example: Selected ESC/POS)
To save the setting value to the memory, press the FEED Switch. Figure 11-2 MS Selection
Message is printed.
To discard the selected item, press the POWER Switch. Function Selection Message is printed
as a sample shown in Figure 11-3. If select "0 Return to MS Selection", function selection is
not performed, and Figure 11-2 MS Selection Message is printed. (Press the POWER Switch
without pressing the FEED Switch.)
To continue to set functions, return to (4).
(8)
To exit the Setting Mode, select "0 : Exit" in Figure 11-2 MS Selection Message. (Press the POWER
Switch without pressing the FEED Switch.)
The test print and Figure 11-1 Mode Selection Message printing start again. Verify that the functions
are properly set.
To return to the print-ready status, select "0 : Normal Mode" in Mode Selection Message. (Press the
POWER Switch without pressing the FEED Switch.)
To set functions again, return to (3).
[Command System]
0 : Return to function selection
1 : ESC/POS
2 : HTML
3 : CPCL
Press the FEED switch an equal number of times to the selected
number. After that, press the POWER SW.
[Command System]
Set ESC/POS
Save setting : Feed SW
Discard setting : Power SW