background image

Installation Instructions TM50/TM80 - MO911/1V0

Page 13

Printed Circuit Board: Adjustments and Connectors

Free Programming

!

ATTENTION: Changing the running-speeds might result in non-conformant force values dependant on the door 
type and the doors‘ weight. To ensure the installation is within legal regulations a force testing as to directive 
EN13241-1 must be made.

1

Free Programming

 

Opening and closing speeds can be set manually when running the free programming 
mode� The length of the soft-stop in closing direction may also be set manually� When 
running the free programming for the first time all speeds are set to maximum�
After changing the DIP-switch settings the red LED will start blinking in intervalls (2 blinks 
- break - 2 blinks) - proceede with step 2�

2

Setting the speeds

Press the LEARN-button followed by the TEST-button and keep 
both pressed for approx� 3 seconds� Release the buttons once 
the red LED starts blinking�

The red LED will blink for up to 8 times followed by a break� 
The mode for programming the speeds is active�

3

Setting the closing speed

The number of blinks of the red LED indicates the entire speed 
setting:  
8 blinks = maximum speed 
1x blink = minimum speed

By means of the black TEST-button the speed can be reduced; 
each press reduces the speed by one step� Wait for the break 
after the blinks and then start counting to evaluate the entire 
speed setting�
By means of the red LEARN-button the speed can be increased�

4

Confirm the selected speed

Press the LEARN-button followed by the TEST-button; keep 
both pressed for approx� 1 second and release them�
You are automatically in the mode for setting the opening 
speed�
The program is now in the mode to set the opening speed�

5

Setting the opening speed

After completing step 4 the red LED is blinking up to 8 times followed by break� Setting the opening speed is made the 
same way as described in step 3 and 4�
After confirming the selected opening speed the LED and the operators‘ lighting will be blinking regularily, the speeds have 
been set successfully�

6

Starting the learning cycles

Shortly press the LEARN-button� The operator will first run in 
opening direction and hit the upper limit block� If you wish 
to keep the standard soft-stop in closing direction, no further 
action is required� Wait until the operator has completed the 
learning cycles (the door will then remain in closed position and 
the operators‘ lighting will stop blinking)� The programming 
then is completed�

7

Changing the length of Soft Stop

Once the learning cycles have started and the upper limit block was hit, the operator will run in closing direction� During 
this first run in closing direction the soft stop may be altered: press the red LEARN-button and keep it pressed� The operator 
will increase speed� Release the LEARN-button where you want the soft stop to start in later operation� The speed will be 
reduced and the new soft stop setting will be safed� Wait until the operator has completed the learning cycles, then the 
programming is completed�

www.thegaragedoorcentre.co.uk

0800 525 442

www.thegaragedoorcentre.co.uk

www.thegaragedoorcentre.co.uk

0800 525 442

www.thegaragedoorcentre.co.uk

Summary of Contents for TM 50

Page 1: ...3 1 TM 50 TM 80 ENGLISH TGarage Door Operator INSTALLATION AND PROGRAMMING INSTRUCTIONS www thegaragedoorcentre co uk 0800 525 442 www thegaragedoorcentre co uk www thegaragedoorcentre co uk 0800 525 442 www thegaragedoorcentre co uk ...

Page 2: ...ogramming Remote Components Free Programming 13 Setting the speeds Setting the opening speed Changing the length of Soft Stop Automatic Closing 14 Setting the time Pre Warning by internal lighting Connecting a Photo Cell Performance of Control Devices Avoiding automatic closing temporarily Further Safety Advice for Automatic Closing Adjusting the Lighting Duration 15 Remote Control Registering and...

Page 3: ...line with one impulse wire C D 24V AC Output max 200mAmp 24 V Programming Running Length and Forces Keep the LEARN button pressed for 3 seconds release it the operators light is now blinking and press it again shortly Remote Components Transmitters Digi Pad Remote Wall Push Button Keep the LEARN button pressed for 3 seconds release it the operators light is now blinking and press the desired hand ...

Page 4: ...nd the installation was made as to the manufacturers instructions the whole installa tion will normally be CE compliant Older Garage Doors When automating an older garage door the TS series will still comply to the regulations through the automatic force setting the requested values for forces and reversion will be according to the regulations But it needs to be taken in consideration that most ol...

Page 5: ...e door manufacturer s manual If possible install the drive at a height of at least 2 10 m and the manual release at a height less than 1 80 m Locate the push button within sight of the door but away from moving parts and at a minimum height of 1 50 m Fix the label warning against entrapment next to the push button The label fixed to the manual release may not be removed After installation ensure t...

Page 6: ...ator the limit blocks must be set up and the operator must be put in programming mode Otherwise the operator will produce an error mes sage Minimum Headroom A minimum distance of 35mm between the garage door and the ceiling is re quired Door Hight No optionals are required for doors up to 2 250mm hight Between 2 250mm und 2 500mm a lintel sided extension for the rail might be required The operator...

Page 7: ...you made in the middle of the garage door Fit the operator to the ceiling when you have made sure the C rail is running straight to the front Use the supplied bracket to fix the C rail to the ceiling 3 5 Now fit the door arm to the garage door 5 Take care that the angle between the operator and the door arm does not exceed a max of 45 it may be lower 6 The limit blocks must be tightened and the pr...

Page 8: ...ont of the trolley Pic 2 If not the block must be moved until it touches the trolley 4 Tighten the blocks screw to keep it in place Take care not to tighten it too strongly the c rail should not be bended 5 Now the garage door needs to be opened manually The trolley will lock into the chain you have to release it once again to fully open the garage door Pic 1 6 The block for the opening direction ...

Page 9: ...opening cycle 4 Check the function of the emergency release together with a second person Stay inside the garage and close the door with the operator Let the second person open the door manually with the door keys If this works the emergency release is mounted properly Do not leave the garage and close the garage door with the operator before you have tested the emergency release When there is a s...

Page 10: ... start the learning cycles When set to free programming then pls refer to page 13 Programming Functions Adjusting the time for the integrated lighting The LERN button must be pressed for approx 6 seconds until the green LED starts blinking then release the button Pressing the button again will confirm the the new time for the integrated lighting Increasing the running speeds When setting the openi...

Page 11: ...ire It must be removed from C D and must be connected to the safety device as shown below If both a photo cell and a hatch door contact must be used then both items must be connected in one line Photo Cell D C 24V 24V 24 V 24 V N C 8 2 kW Hatch Door Contact C D 8 2 kW Standard function Openings If the device detects an obstacle within approx 2 seconds after running from closed position then the op...

Page 12: ...nt and running distance it hits the OPENING limit block it closes slowly until it reaches CLOSED position it opens fast until it reaches OPEN position it closes fast until it reaches CLOSED position The operators light keeps blinking for a little while after the operator stops running Once the operators light stops blinking the programming has been successful Programming Remote Components 1 Keep t...

Page 13: ...ess the LEARN button followed by the TEST button keep both pressed for approx 1 second and release them You are automatically in the mode for setting the opening speed The program is now in the mode to set the opening speed 5 Setting the opening speed After completing step 4 the red LED is blinking up to 8 times followed by break Setting the opening speed is made the same way as described in step ...

Page 14: ...warning lights may connected together with the integrated operators lighting using the connectors 5 6 230V 160 Watts max The operators housing must be removed in order to access the connectors Cabling and connections of 230V components may only be done my authorised professionals 3 Connecting a Photo Cell As a non contact safety device a photo cell must be connect when using the automatic closing ...

Page 15: ...l be switched on with every incoming command The adjusted time will run from the moment the command was received Factory pre set the light will stay on for 3 minutes This time may be changed in steps of 10 seconds up to a total of 10 minutes To change the time proceede as follows 1 Keep the red LEARN button pressed for 6 seconds Release the button once the green LED comes on 2 Press the red LEARN ...

Page 16: ... Pressing the devices but ton again will run the operator Repeat steps 1 and 2 for any further device HomeLink Integrated car remotes usually use the HomeLink system by Johnson Controls Systems from version 6 or higher are com patible with the operator First the hand transmitter must be copied into the HomeLink module closer information on your specific system can be found on the internet www euro...

Page 17: ...h a lower range than in an ordi nary garage build of stone The more steel was used for the walls the shorter the range of your remote control Remote control activity in the area Radio and television transmitters close to your garage might reduce the range Older baby phones and other household remote equipment Some equipment like remote head phones and baby phone might prodecure strong disturbant s...

Page 18: ...he chain Internal Wiring 1 Blue mains supply 230V 2 Brown mains supply 230V 3 Black transformer 230V 4 Black transformer 230V 5 Brown Lighting 230V 6 Blue Lighting 230V External connections A B Floating connector for push button key switch and the impulse cables of an external receiver C D Floating connector with a 8 2kOhm resistor for impulse cables from a photo cell receiver 24V 24V AC for a pho...

Page 19: ...ceiver is disconnected If so the remote trans mitter or receiver might be defective The operator reacts on the push button but not on the transmitter Check the battery of the transmitter Try registering the transmitter with the operator page 16 The operator neither reacts on the push button nor on the transmitter Disconnect the receiver or remove the transmitter battery Use your push button switch...

Page 20: ...wide and 2 50m high as to 06 02 2012 Prüfungen beantragt für Kipp und Sektionaltore bis zu 5m Breite und 2 50m Höhe Stand 06 02 2012 Document No AN 02122011 Dokument Nr AN 02122011 in accordance with the Radio and Telecommunications Ter minal Equipment Act FTEG and Directive 1999 5 EC R TTE Directive Gemäß dem Gesetz über Funkanlagen und Telekommunikations endeinrichtungen FTEG und der Richtlinie ...

Reviews: