Endschaltereinstellung
Installation Instruction UK
-
Page 4
"OPENING"
limit-switch actuator
Your UK garage door opener automatically stops when one
of the red limit-switch actuators trips a limit switch
(in either "closing" or "opening" dirction).
Adjust the limit switches
by hand
"Opening" direction
Please set the limit-switch
actuator for the "opening"
direction so that the door
comes to a halt about 30
mm (1,2") before its final
resting position
"Closing" direction
Please set the limit-switch
actuator for the "closing"
direction so that the door
lightly touches the door
frame when closed.
"CLOSING"
limit-switch
"CLOSING"
limit switch actuator
"OPENING"
limit switch
Speed switch
S1
Your UK 80 or UK 100 garage door opener lets you
choose from among two different speeds.
This is done with the aid of switch
S1
, which is on
the
top of the drive unit. The following two speeds are
preset in the factory:
1: 13 cm (4,7")/sec. (brown cable, 28 V AC)
2: 9 cm (3,5")/sec. (blue cable, 22 V AC)
You can easyly select either of these speeds by
changing the position of the speed switch.
Setting of the speed
(UK 80 and UK 100 only)
Summary of Contents for UK 100
Page 9: ...Problems No problem...