POLR020001SE 039609 060622
9
Note: Make sure the polarity of the sensor is respected.
6.0 PRECAUTIONS
1.
While you are using the instrument, the pressure of the refrigeration system should be no more than 50psi, and the search area should be
almost draft-free. If there is wind, refrigerant gas escaping from the leak will be quickly dispersed away from the source, thus compromising
gas measurement and detection.
2.
The Autozero function is on by default, so when the detector turns on and detects refrigerant gas, it will autozero the with the value of
refrigerant gas in the room at that time. In case Autozero is disabled, you have to press ‘RESET’ button briefly to zero the gas concentration
manually.
3.
The most likely sources of gas leaks are in places polluted with oil or dust and pipe joints. These places should be checked as a priority.
4.
The sensor should ideally be kept 3 ... 5 mm (1/8 ... 1/4 inch) from the suspected leak while searching, so as to preserve the sensor from
environmental pollution that could interfere with the accuracy of the sensor. We recommend moving the probe at a speed to cover 25 ... 50
mm per second (1 or 2 inches/second).
5.
It is forbidden to bring the sensor into direct contact with an environment with a concentration higher than 30,000 ppm refrigerant gas.
7.0 TECHNICAL FEATURES
Power supply:
3 x 1,5V AA (alkaline batteries - supplied) or 3 x 1,5V AA (rechargeable batteries Ni-Mh)
Rechargeable batteries (not provided) recharge with external charger (not provided)
Gases detected:
R12,R11,R500,R503 (CFC)
R22,R123,R124,R502 (HCFC)
R134a,R404a,R410a,R407a,R32 (HFC)
R600a,R290 (HC)
R1234YF (HFO)
Sensor
type:
Semiconductor
Sensor life:
>1 year
Sensor warm-up time:
30 seconds
Minimum detectable gas measurement: ≥3 gr/year.
Replaceable sensor:
Interchangeable by the user
Response time:
≤
3 seconds
Measurement indication:
Horizontal bars levels 0-7
Automatic shutdown function:
User-settable
Autozero:
Automatic / Manual
Display:
In colored segments
Acoustic
indicator:
Buzzer
Operating temp:
0°C .. +50°C
Storage temperature:
-20°C .. +70°C
Moisture limits:
20% .. 80% RH non-condensing
Case size:
430x245x70 mm (LxAxP)
Flexible stem length:
420mm
8.0 WARRANTY
In the interest of continuous development of its products, the manufacturer reserves the right to make changes in technical data and performance
without prior notice. The consumer is guaranteed against product conformity defects according to the European Directive 2019/771 as well as
the Seitron warranty policy document. The full text of the warranty is available from the seller upon request.
Warning!
the sensor and its housing must have good contact.