0000137242 Rev.5.1
19
4.3.2 CHLORINE MEASUREMENT SETTINGS MENU (menu index 3B)
Use the
UP
and
DOWN
keys to scroll through the various menus and submenus and to modify the data
(increase/decrease).
Use the
ENTER
key to access the data insertion submenus and to confirm any modifications.
The various items contained within the Chlorine measurement sub-menus are described below:
•
Menu index “3B1” CHLORINE RELAY
The various items contained within the Chlorine relay’s sub-menus are described below, with their various modes,
ranges and settings:
Item
Default Value
Range
On/Off
:
SetPoint:
1.2 ppm
0-5 ppm
Dose Type:
Low
High / Low
Hysteresis:
Off
0.1-3 ppm
Hysteresis Time:
Off
1-900 Seconds
Start Delay:
Off
3-900 Seconds
Stop Delay:
Off
3-900 Seconds
Timed
SetPoint:
1.2 ppm
0-5 ppm
Dose Type:
Low
High / Low
Hysteresis:
Off
0.1-3 ppm
Hysteresis Time:
Off
1-900 Seconds
Start Delay:
Off
3-900 Seconds
Stop Delay:
Off
3-900 Seconds
On Time:
1
1-1800 Sec
Off Time:
1
1-1800 Sec
PWM (Proportional)
SetPoint:
1.2 ppm
0-5 ppm
Dose Type:
Low
High / Low
Hysteresis:
Off
0.1-3 ppm
Hysteresis Time:
Off
1-900 Seconds
Start Delay:
Off
3-900 Seconds
Stop Delay:
Off
3-900 Seconds
Period:
20 seconds
20-1800
Proportional Band:
0.6 ppm
0.3-3 ppm
3B CHLORINE DOSING
3B1 RELAY ON/OFF
3B2 FMW
3B3 OUTmA
↓
3B CHLORINE DOSING
3B3 OUTmA
↑
3B4 ALARMS
3B5 REF. TEMP.: 25.0°C
3B1 CHLORINE RELAY
>ON/OFF
TIMED
PWM
The Chlorine relay’s settings can be varied as
follows:
•
ON/OFF (SetPoint threshold dosing)
•
TIMED (Timed dosing)
•
PWM (Proportional dosing)
•