background image

0000137188                                                          Rev. 1.0 

 

 

 

 

 

User Manual 

 

 
 
 

 

 

Summary of Contents for Pool Basic Pro Evo

Page 1: ...0000137188 Rev 1 0 1 User Manual ...

Page 2: ... EXAMPLE 7 6 DESCRIPTION OF THE CIRCUIT 8 7 CALIBRATION MENU 8 7 1 CALIBRATION 8 8 PROGRAMMING 10 9 DOSING METHOD 13 9 1 PH PROPORTIONAL DOSING 13 9 2 ON OFF PH DOSING 13 9 3 ALARM FOR THE PH SET POINT 14 10 ACTIVATIONS 15 11 ALARMS 15 12 PRE DEFINED CONTROL PARAMETERS 15 13 LIST OF POSSIBLE ANOMALIES AND RELATIVE SOLUTIONS 16 14 HANDLING 17 15 STORING THE PUMP AFTER USE 18 WARNINGS 18 ...

Page 3: ... IN THE PRESENT MANUAL COULD CAUSE INJURY TO PEOPLE AND OR DAMAGE TO THE DEVICE WARNING During installation of the Pool Basic Pro EVO device proceed as follows Make sure that the supply voltage coincides with the one indicated on the label on the side of the device Make sure that the injection pressure is below 1 5 bar Make sure that the pump s protective cover is properly latched Make sure that t...

Page 4: ...4X6 5 m x 2 D pH Electrode model SPH 1 E Reducer for injection valve x 2 F Duckbill valve in FPM 3 8 GAS x 2 G Suction foot PVC hose x 2 H Tapping double bolt clamp for fastening PSS3 probe holder onto 2 50mm hose I Tapping double bolt clamp for fastening injection valve onto 2 50mm hose x 2 J Probe holder model PSS3 1 2 GAS K Hose 3x7 L Fixing bracket kit M pH 4 pH 7 H2O Buffer solution kit N Ins...

Page 5: ...rm 10 A 250 V dry contact Relay for H2O2 10 A 250 V dry contact Dedicated power for pumps 240 Vac 10 watt Input signal 100 240 Vac Level probe pH H2O2 Install the Pool Basic Pro EVO control device on a hard support vertical wall where it can be easily accessed by the operator Attach the Pool Basic Pro EVO control device using the provided fixing bracket distance between centre of holes 95mm Hole Ø...

Page 6: ...ENTAZIONE PER POMPE GROSSE PER EVITARE DISTURBI DI CORRENTE 3 1 2 5 4 6 0 7 Lunghezza massima de cavo 6 mt Pressione Massima 1 5 bar NOTA 2 NOTA 1 NOTE 1 FOR LARGE PUMPS THE CABLE MUST PASS THROUGH AN AREA OTHER THAN THE POWER SUPPLY ZONE IN ORDER TO PREVENT CURRENT DISTURBANCES NOTE 2 THE MAX PRESSURE MUST NOT EXCEED 1 5 BAR TO INCREASE THE HOSE S LIFETIME THE PRESSURE MUST NOT EXCEED 1 BAR Max l...

Page 7: ...88 Rev 1 0 7 5 1 APPLICATION EXAMPLE PH Note The linear distance of the hose between the probe and the point of injection must not be less than 60cm COMPENSATION TANK RECIRCULATION PUMP FILTER HEAT INTERCHANGER ...

Page 8: ...O2 pump 7 CALIBRATION MENU 7 1 Calibration Before proceeding the calibration must be enabled Scroll down the menu Advanced Cal the display will show Exit the menu and return to the normal system status Calibration Menu Display Settings Advanced Cal Off Press ENTER to access the menu Advanced Cal Full Press ENTER and the and keys to modify the calibration Select Full and confirm with ENTER Al arm R...

Page 9: ...lution pH 7 Press CAL B Solution 7pH The calibration takes 1 minute Wait 59s B Solution 7pH Probe quality Quality B Solution 7pH H O 2 2 9 Wash the probe 4 pH 3 10 Keep the probe in the buffer solution pH 4 Press Cal to start calibration with a buffer solution pH 4 Press CAL B Solution 4pH The calibration takes 1 minute Wiat 59s B Solution 4pH Probe quality Quality B Solution 4pH H O 2 2 14 Wash t...

Page 10: ... Measure Setpoint 7 4 pH Press Enter and the and keys to change the Set Point value 0 14 pH pH Measure Sp Type Acid Press Enter and the and keys to change the Set Point type Acid Alkaline pH Measure OFA Time Off Press Enter and the and keys to set the OFA time to OFF or from 1 to 240 min see Paragraph 9 5 pH Measure Alr Band 3 0pH Press Enter and the and keys to set the band alarm from 1 to 3 pH p...

Page 11: ... to 100m h Advanced Display Settings Progrma Menu Avdvanced Use Enter to access the sub menus Temp Flow Cal Password Avdvanced Temp 25 C Press Enter and the and keys to set the compensation temperature from 1 to 100 C If a temperature probe is connected the menu item will not be displayed as the system will compensate automatically with the value read by the probe itself Avdvanced Flow On Press En...

Page 12: ...Stand by display Operation Alr Tm 25 C 8 3pH Alr 1200cc Tm 25 C 8 3pH Alr H2O2 37m Tm 25 C 8 3pH The display is divided into 4 parts On the upper left hand side the alarm is shown when present On the upper right hand side three views are displayed o The first is the stand by system o The second shows the cc countdown dosed by the pump o The third is the waiting time until the next dosing with the ...

Page 13: ...oportional dosing The instrument allows the chemical measurement to be controlled and modified through the pH Set Point automatically adjusting the dosing though the pH motor controlled in Proportional Time The dosing below is obtained by setting the following parameters Set point pH 7 20 pH Type of Dosing Alkaline Proportional Band 0 80 pH Set Point pH Prop Band Motore pH ...

Page 14: ...t a work window is created If the allowed limits are exceeded the alarm relay closes and remains closed until the measurement is reset or the enter key is pressed to deactivate the alarm When the OFA time Over Feed Alarm is set the dosing time of Set Point pH in time is controlled with two alarms First alarm at 70 of the time set is seen on the display the alarm relay closes Second alarm at 100 of...

Page 15: ...etPoint of the band value set At 70 of the time set the system shows and activates the alarm relay at 100 it blocks the motor Press the Enter key to reset the alarm Press the Enter key with the alarm active and its relay is deactivated only remaining shown on the display 12 PRE DEFINED CONTROL PARAMETERS To reset default values and settings Disconnect the device Hold down the and keys simultaneous...

Page 16: ...calibrate the pH 7 value Error shown on the display Calibration quality of pH probe 20 Unsuitable buffer solution Make sure that the solution used is pH 7 Check the buffer solution pH using an electronic pH meter Use a new pH 7 buffer solution and restart calibration Problem on probe s porous material dirt deposits Make sure that the probe s porous material is in good condition wash the electrode ...

Page 17: ...s freed up to the right connector Position the roller at 20 past 10 turning it in the direction of the circular arrow Insert the left connector into the relative housing and pass the hose under the roller s guide Turn the probe holder in the direction of the circular arrow simultaneously accompanying the hose into the pump s head until the right connector is reached Arrows indicating the liquid s ...

Page 18: ...ation device must be stored clean water should be pumped through the hose in order to rinse it Then position the probe holder at 7h05 turning in the direction indicated by the circular arrow These two precautions will facilitate the subsequent reactivation of the unit ...

Page 19: ... holder Store it in the original bottle filled with tap water If necessary close the probe holder using a plug the size of a 5 euro cent coin Since the pH electrode consists of glass parts handle it with care All of our electrodes are tested on the production line before being packaged Repairs of electrodes are not foreseen by the warranty unless they do not function when they are activated for th...

Reviews: