SR-1800
Rotary and DIP Switch Settings
The device is shipped from the factory with default settings. Configure the number of lines to
read and device function settings according to its intended use.
If the RS-232C port is used, configure the communication speed and data format settings.
1
Accessing the Rotary and DIP Switches
(1) Remove the stacker from the main body unit.
(2) Bend and remove the DIP switch cover on the bottom left of the stacker side.
(Reattach it after set up is complete.)
2
Rotary Switch RSW1 Settings
Set the communication speed of the RS-232C port.
CAUTION
· Be careful when configuring settings. Communication errors will occur if settings are
incorrect.
· Make sure the power is off when configuring settings.
: Indicates the factory settings.
SW No.
Baud rate [bps]
0
9,600
1
19,200
2
38,400
3
57,600
4
115,200
5 to 9
(Not used)
RSW1
SW1
SW2
SW3
RSW2
DIP switch cover
RSW1
SW1
SW2
SW3
RSW2