Relay Word Bits
Definitions
RTD7T
RTD7 Trip.
24
RTD8A
RTD8 Alarm.
24
RTD8T
RTD8 Trip.
24
RTD9A
RTD9 Alarm.
25
RTD9T
RTD9 Trip.
25
RTDFLT
Asserts when an open or short circuit condition is detected on any enabled RTD input, or commu-
nication with the external RTD module has been interrupted.
22
RTDIN
Indicates status of contact connected to an SEL-2600 RTD Module.
22
SALARM
Pulses for the following conditions: Setting Changes, Access Level Changes, and three unsuc-
cessful password entry attempts.
13
SC01QD to SC08QD
SEL
OGIC
Counters 01 through 08 asserted when counter = 0.
56
SC01QU to SC08QU
SEL
OGIC
Counters 01 through 08 asserted when counter = preset value.
55
SC09QD to SC16QD
SEL
OGIC
Counters 09 through 16 asserted when counter = 0.
58
SC09QU to SC16QU
SEL
OGIC
Counters 09 through 16 asserted when counter = preset value.
57
SC17QD to SC24QD
SEL
OGIC
Counters 17 through 24 asserted when counter = 0.
60
SC17QU to SC24QU
SEL
OGIC
Counters 17 through 24 asserted when counter = preset value.
59
SC25QD to SC32QD
SEL
OGIC
Counters 25 through 32 asserted when counter = 0.
62
SC25QU to SC32QU
SEL
OGIC
Counters 25 through 32 asserted when counter = preset value.
61
SF
Slip frequency of voltages VP and VS is less than setting 25SF.
110
SG
n
Setting Group
n
active, where
n
= 1 to 3.
28
SH0
Reclosing relay shot counter = 0
26
SH1
Reclosing relay shot counter = 1
26
SH2
Reclosing relay shot counter = 2
26
SH3
Reclosing relay shot counter = 3
26
SH4
Reclosing relay shot counter = 4
26
SV
nn
SEL
OGIC
control equation variable timer input SV
nn
asserted, where
nn
= 01 to 08
(see
).
43
SV
nn
SEL
OGIC
control equation variable timer input SV
nn
asserted, where
nn
= 09 to 16 (see
).
45
SV
nn
SEL
OGIC
control equation variable timer input SV
nn
asserted, where
nn
= 17 to 24 (see
).
47
SV
nn
SEL
OGIC
control equation variable timer input SV
nn
asserted, where
nn
= 25 to 32 (see
).
49
SV
nn
T
SEL
OGIC
control equation variable timer output SV
nn
T asserted, where
nn
= 01 to 08
(see
).
44
SV
nn
T
SEL
OGIC
control equation variable timer output SV
nn
T asserted, where
nn
= 09 to 16 (see
).
46
SV
nn
T
SEL
OGIC
control equation variable timer output SV
nn
T asserted, where
nn
= 17 to 24 (see
).
48
SV
nn
T
SEL
OGIC
control equation variable timer output SV
nn
T asserted, where
nn
= 25 to 32 (see
).
50
T01_LED
Asserts when the SEL
OGIC
control equation T01_LED result is logical 1 (see
).
34
T02_LED
Asserts when the SEL
OGIC
control equation T02_LED result is logical 1 (see
).
34
T03_LED
Asserts when the SEL
OGIC
control equation T03_LED result is logical 1 (see
).
34
Table J.2
Relay Word Bit Definitions for the SEL-751A
(Sheet 9 of 11)
Bit
Definition
Row
Summary of Contents for 751A
Page 1: ...20100129 SEL 751A Feeder Protection Relay Instruction Manual PM751A 01 NB...
Page 6: ...This page intentionally left blank...
Page 12: ...This page intentionally left blank...
Page 18: ...This page intentionally left blank...
Page 26: ...This page intentionally left blank...
Page 92: ...This page intentionally left blank...
Page 218: ...This page intentionally left blank...
Page 250: ...This page intentionally left blank...
Page 376: ...This page intentionally left blank...
Page 392: ...This page intentionally left blank...
Page 408: ...This page intentionally left blank...
Page 418: ...This page intentionally left blank...
Page 434: ...This page intentionally left blank...
Page 462: ...This page intentionally left blank...
Page 544: ...This page intentionally left blank...
Page 580: ...This page intentionally left blank...
Page 584: ...This page intentionally left blank...
Page 632: ...This page intentionally left blank...
Page 636: ...This page intentionally left blank...
Page 640: ...This page intentionally left blank...