Schweitzer Engineering Laboratories, Inc.

SEL-9192 Data Sheet

Utility Grade Dial-Up Access

Major Features and Benefits

The SEL-9192 Utility Grade USB Modem provides traditional dial-up access to remote locations where harsh
utility grade environmental specifications are required.

Wide Temperature Range. 

Operation temperature from –40° to +85°C (–40° to +185°F).

Standard Input Voltage. 

Input voltage 5–30 Vdc. Power from an external source, through the USB-B

connector, or through the DB-9 connector.

Easy Configuration. 

Uses standard and extended AT command set.

Compression and Speed. 

Allows data speeds from 300 bps to 56 kbps. Supports V.44 and V.42bis

data compression.

Durable and Reliable. 

Includes Telco line surge protection, a rugged case, and SEL’s 10-year warranty.

Functional Overview

The SEL-9192 is a 56 kbps dial-up modem built to withstand the extremely harsh conditions in a utility envi-
ronment. Connect RTUs, communications processors, and other equipment for dial-up or dial-out engineer-
ing access or data acquisition through the DB-9 serial or USB-B connectors. Power the SEL-9192 with the
optional power supply, or internally through connected USB-B or DB-9 serial ports. Configuration is simple
with the extended AT command set (listed in 

Table 1

).

SEL-9192 Utility Grade
USB Modem

Summary of Contents for SEL-9192

Page 1: ...ommand set Compression and Speed Allows data speeds from 300 bps to 56 kbps Supports V 44 and V 42bis data compression Durable and Reliable Includes Telco line surge protection a rugged case and SEL s 10 year warranty Functional Overview The SEL 9192 is a 56 kbps dial up modem built to withstand the extremely harsh conditions in a utility envi ronment Connect RTUs communications processors and oth...

Page 2: ...ure 1 Dial Up or Dial Out Point to Point SCADA Communication Figure 2 illustrates use of the SEL 9192 in a point to multipoint SCADA communications scheme The host computer can access any number of dial up devices by serially dialing each SEL 9192 connected to those end devices Figure 2 Dial Up Point to Multipoint SCADA Communication Add an SEL 3025 to your dial up network to create a secure dial ...

Page 3: ...pports 5 Vdc power output on serial Pin 1 connect an SEL C431 cable to the modem and DTE device Locate the 5 V Pin 8 switch positioned between the Telco and DB 9 connectors Slide the switch to the ON position to use port power on Pin 8 or slide the switch to the OFF position to use a straight through serial cable with no power on Pin 8 Use the SEL C431 cable to connect to an SEL DTE device in a DN...

Page 4: ...nstallation to finish then click Finish For Windows 7 64 bit perform the following steps Step 1 Ensure that you have installed the SEL USB to UART and downloaded the Windows 7 modem driver from the SEL 9192 modem webpage on the SEL website Step 2 Connect the SEL 9192 modem to the PC using a USB B cable Wait until the modem power LED is illuminated Step 3 From the Start menu open Control Panel Syst...

Page 5: ...ence Pause the modem pauses for a time specified by S8 before dialing the following digits Most often used when dialing an outside line through a PBX Return to command mode after processing command Disable calling tone transmission applicable to current dial attempt only Example of the Dial command ATDT767 8900 Meaning ATtention Dial using Touch tone the numbers 767 8900 En Command echo E0 Disable...

Page 6: ...not detected NO CARRIER will be reported instead of NO DIALTONE X2 Disables monitoring of busy tones Sends only OK CONNECT RING NO CARRIER ERROR NO DIALTONE and CONNECT XXXX If busy tone detection is enforced and busy tone is detected NO CARRIER will be reported instead of BUSY If dial tone detection is enforced or selected and dial tone is not detected NO CARRIER will be reported instead of NO DI...

Page 7: ...peed parity settings AT commands and S registers Modem will default to the saved settings upon power up or reset W0 Saves the current configuration to stored profile 0 W1 Saves the current configuration to stored profile 1 V Displays current configuration Zn x Store telephone number to location n n 0 3 Enter store number location x Dial String Enter telephone number to store Entering AT Z2 7678900...

Page 8: ...ignal quality Reports line signal quality DAA dependent Returns higher order byte of the EQM value Based on EQM value retrain or fallback fall forward may be initiated if enabled by E1 or E2 Table 3 AT Commands Sheet 2 of 2 Command Description Table 4 STE Command Options STE n Value Extension Pickup Line In Use 0 default Disabled Disabled 1 Disabled Enabled 2 Enabled Disabled 3 Enabled Enabled Whe...

Page 9: ...egister Range Units Default Description S0 0 255 Rings 0 Ring to answer on ATS0 1 means answer call on first ring detected S1 0 255 Rings 0 Number of rings counted S2 0 127 ASCII 43 Escape code character S3 0 127 ASCII 13 Command terminator carriage return character or the enter key S4 0 127 ASCII 10 Line feed character S5 0 127 ASCII 8 Back space character S6 2 255 Seconds 2 Wait time for dial to...

Page 10: ...wledged the command 1 CONNECT Connection made at 300 bps or extended result codes are off X0 2 RING An incoming ring signal has been detected 3 NO CARRIER Reflects either an intended disconnect or a failure to complete a connection 4 ERROR An invalid command was issued to the modem 5 CONNECT 1200 Indicates a 1200 bps line or DTE connection see the Wn command in Table 1 6 NO DIALTONE The modem cann...

Page 11: ...Schweitzer Engineering Laboratories Inc SEL 9192 Data Sheet 11 Mechanical Diagrams Figure 7 SEL 9192 Top Front and Rear Panels Figure 8 SEL 9192 Surface Mount Dimensions ...

Page 12: ...k must comply with the applicable 47 CFR Part 68 rules and requirements adopted by the ACTA It s designed to be connected to a compatible modular jack that is also compliant 3 The ringer equivalence number REN is used to determine the number of devices that may be connected to a telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call ...

Page 13: ... 2 2008 Severity Level 2 4 6 8 kV contact 2 4 8 15 kV air IEC 61000 4 2 2008 Severity Level 2 4 6 8 kV contact 2 4 8 15 kV air IEEE C37 90 3 2001 Severity Level 2 4 and 8 kV contact 4 8 and 15 kV air Fast Transient Burst Immunity IEC 60255 22 4 2008 Severity Level Class A 4 kV 5 kHz 2 kV 5 kHz on communications ports IEC 61000 4 4 2011 Severity Level 4 kV 5 kHz Radiated Digital Radio Telephone RF ...

Page 14: ...SEL 9192 Data Sheet Schweitzer Engineering Laboratories Inc 14 Notes ...

Page 15: ...Schweitzer Engineering Laboratories Inc SEL 9192 Data Sheet 15 ...

Page 16: ...Sch weitzer Engineering Laboratories Inc reserves all rights and benefits afforded under federal and international copyright and patent laws in its products including without limita tion software firmware and documentation The information in this document is provided for informational use only and is subject to change without notice Schweitzer Engineering Laboratories Inc has approved only the Eng...