Current  user  manual  (further  in  text  –UM) contains  description  of  operation  and  use  of  the 

device of active information protection through power lines and ground (controlled noise generator 
through  mains)  SEL  SP-44  (further  in  text-  device)  according  to  purpose,  is  assigned  for  correct 
installation, configuration and exploitation.  

Normal  operation  conditions  -  in  premises  with  artificially  regulated  climatic  conditions: 

ambient  temperature  from  +5  till  +45  °С,  air  humidity  not  more  than  80%  at  the  temperature  of 
+25°С. 

 

PURPOSE AND OPERATION PRINCIPLE 

Device  SEL  SP-44  is  designed  for  protection  of  information  containing  data  of  federal 

importance or other data with restricted access, processed by the technical means and systems, from 
leakage through interferences by forming masking noise interferences. 

Device SEL SP-44 – corresponds to type “B”- means of active protection of information from 

leakage through induction of informational signal on the conductors, as well as ground circuits and 
power  supply, electro  conductive  line  and  engineered technical  communications,  going beyond  the 
controlled zone. 

 

  Factory settings of the device SEL SP - 44: 

1) The minimal level of integrated noise signal is set. 
2) Remote turn on of the working mode is turned off.  
3) Password for settings  _______________ 

 

1.

 

TECHNICAL CHARACTERISTICS  

Device SEL SP-44 itself is a two-channel generator of masking noise signal for mains and 

ground (“phase”-“ground” and “zero”- “ground”)  

Functionality and setup/re-setup of the device is done under control of microprocessor with 

the energy independent memory. 

Diagnostics of functionality- continuous, automatic.  
Indication of operation: LCD-indicator, sound and light. 
 

1.2. Operation modes: 

▪ Working mode - Generation of noise signals through mains and ground. 
▪ Setup mode – re setup of levels of noise signals through mains and grounding 
Device does not create interference for calculating devices and home appliances. 

 

1.3. Main technical parameters and functions 

 

1) Frequency diapason of generated noise signals ....................... 0.01 – 400 MHz. 
2) The level of noise signals on the mains plug at a load of 50 Ohms relative to 1 mV/√kHz, 

must comply with: 

10 kHz  ÷   50 kHz .......................................................................... 45 - 70 dB 
50 kHz  ÷ 150 kHz .......................................................................... 15 - 50 dB 

Summary of Contents for SEL SP-44

Page 1: ...www SELCOMSECURITY com DEVICE FOR PROTECTION OF POWER LINES AND GROUND Controlled noise generator through power lines and ground SEL SP 44 USER MANUAL 2016 ...

Page 2: ...tors as well as ground circuits and power supply electro conductive line and engineered technical communications going beyond the controlled zone Factory settings of the device SEL SP 44 1 The minimal level of integrated noise signal is set 2 Remote turn on of the working mode is turned off 3 Password for settings _______________ 1 TECHNICAL CHARACTERISTICS Device SEL SP 44 itself is a two channel...

Page 3: ... 220V 50 60 Hz 11 Power consumption 12 Watt 12 Dimensions and weight not more than 180х180х50 mm 1 5 kg 13 Time until failure not less than 6000 hours 14 Service life not less than 7 years when the resource is not less than 27000 hours 2 DELIVERY SET 3 PREPARATION FOR USE 3 1 Safety measures Electrical safety of the device is carried out by grounding through the grounding contact of the mains plug...

Page 4: ...y turn on the device Connection of the wired switch is made through the RC connector on the rear surface of the device Wired switch normally open with fixation It connects to pins 1 and 2 of the RC connector To indicate the generation of a noise signal an led 3 cathode 4 anode can be connected to the same connector 3 3 2 Power connection disconnection 1 Power Supply Connection connect the device t...

Page 5: ...igh frequency noise level setting Further by pressing the MENU OK or C buttons MENU OK to confirm the selected parameter for setting the C cancels the selected setting 2 Exiting Setting mode To exit setting mode press the C button 3 Setting the noise signal level The noise level is set separately for the low frequency LF and high frequency HF bands The initial state of the setting is selected acco...

Page 6: ...s LEDs OUTPUT LF and OUTPUT HF on the front panel of the device are green 4 3 Turn off the operating mode Turn off operating mode 1 When you prohibit the use of remote switching factory setting by pressing and holding the C button on the front panel of the device till LCD switches off 2 When allowing the use of remote on switch toggle switch to the 0 off the LED switch is off 4 4 The order of the ...