background image

 

Warranty 

 

 

 

 

 

The Silvan 

Warranty 

 

This 

warranty

 is the only warranty applicable to Silvan new products ('Products') and, to the 

maximum extent permitted by law, is expressly in lieu of any other conditions or warranties 
expressed or implied in relation to the Products.   
Subject only to legislative obligations to the contrary, Silvan shall not be liable for incidental or 
consequential damage resulting from ownership or use of a Product.

 

Silvan does not authorize any person to create for it any other obligation or liability in connection 
with these products. 

 
Silvan warrants its authorised Dealer, who in turn warrants the original purchaser (owner) of each new 
Silvan product that it will repair or replace the product, or, pay the cost of repair or replacement, as 
determined by Silvan without charge for labour or any defective or malfunctioning parts in accordance with 
the warranty limitations and adjustment schedule below. 
The warranty period begins on the date the product is delivered to the first retail purchaser for a period of 
12 months 

This Warranty Covers 

 

Only conditions resulting directly from defects in workmanship or material under normal use and service. 

Warranty Exclusions 

 

The Warranty does not cover: 

 

Conditions  resulting  from  misuse,  use  of  incompatible  chemicals,  exceeding  machine 
specifications including overloading, impact damage,  negligence, accidental damage or failure to 
perform recommended maintenance services. 

 

Any  product  which  has  been  repaired  by  other  than an  authorised  Silvan  service  outlet in  a  way 
which, in the sole and absolute judgement of Silvan, adversely affect its performance or reliability. 

 

The replacement of maintenance items such as diaphragms, batteries, V belts and ground engaging 
components, etc. 

 

Loss  of  time,  inconvenience,  loss  of  use  of  the  product  liability  to  third  parties  or  any  other 
consequential damages. 

 

Incidental costs associated with a warranty repair including any travel costs, out of hour’s labour 
charges, cleaning costs, transportation costs, freight costs or any communication costs.  

 
The repair of a defective product qualifying under this warranty will be performed by any authorised 
Silvan service outlet within a reasonable time following the delivery of the product, at the cost of the 
owner, to the service outlet’s place of business.  The product will be repaired or replaced, using new parts 
supplied by Silvan.  Silvan, in its absolute discretion, may choose to pay the cost of replacement or repair 
of the product. 
 

The owner is responsible for the performance of regular maintenance services as specified in the 
Owner/Operator Manual applicable to the product. Failure to carry out regular maintenance may invalidate 
warranty

 

Summary of Contents for LBA-100

Page 1: ...Operator s Manual MANLBA 100 Rev E 3 10 07 Selecta Power Pump Units 6 5 HP Fire Pump 1 stage 6 5 HP Fire Pump 2 stage 6 5 HP Transfer Pump 2 6 5 HP Transfer Pump 3...

Page 2: ...are has been taken to make it as complete and accurate as possible The information illustrations and technical data were considered to be correct at the time of preparation In accordance with our poli...

Page 3: ...he pump s operation maintenance and safety procedures Now that you are a proud Silvan owner all our services and dealer support are available to you should you need them We assure you of our best atte...

Page 4: ...25 mm 1 X 1 5 inch BSP 38mm Model LBA 100 Fire Pump 2 stage Max Output Open flow 250 l min Max Pressure No Flow 7 Bar 100psi 70m Suction lift height 3 5 metres Inlet connection 1 5 inch BSP 38 mm Out...

Page 5: ...misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services Any produc...

Page 6: ...pump in a well ventilated and well lit area that is free from flammable or other materials that may interfere with its safe operation Never operate in an enclosed area as engine exhaust fumes contain...

Page 7: ...eration the water supply is exhausted stop the engine immediately and fill the pump once it cools down Engine Pre Starting Checks 1 Oil Level Caution The engine is shipped without oil It must be fille...

Page 8: ...on Set the throttle to the full open position to obtain maximum pump output If necessary the flow rate can be regulated by adjusting the throttle position Stopping the Engine To stop the engine under...

Page 9: ...ber Clean After every 500 hours 3 Fuel tank strainer Clean O 3 Fuel supply pipe Check Every 2 years replace if necessary 3 Pump impeller Inspect O 3 Pump housing Inspect O 3 Pump inlet valve Inspect O...

Page 10: ...on the air cleaner base making sure the gasket is in place Tighten the lower wing nut firmly then install the air cleaner cover and tighten the upper wing nut Fuel Sediment Cup Move the fuel valve to...

Page 11: ...hy storage it is best to drain the fuel tank into a suitable container by setting the fuel valve to on and removing the sediment cup and the drain plug from the carburettor Reinstall the sediment cup...

Page 12: ...LTD ABN 48 099 851 144 Melbourne Australia Telephone 61 03 9887 2788 Facsimile 61 03 9887 1035 www silvan com au SILVAN NEW ZEALAND PTY LTD Hamilton New Zealand Telephone 64 07 8496030 Fax 64 07 84960...

Reviews: