SE10 Manual
10
Selectronic Australia
LED (2)
AC Overload should normally remain OFF. If the inverter shuts
down due to too much AC load being drawn from it then LED (2) will come
ON. The SE10 will remain in this condition for 1 minute after the AC load
has been decreased to a safe level.
•
If the inverter remains in this condition after one minute, switch (12)
should be turned OFF and then back ON.
•
When switch (12) is turned OFF any adjustments made to the factory
settings will be lost.
LED (3)
DC Volts Low / High
should normally remain OFF. If the inverter
shuts down because the battery volts are too high then this LED (3) will
come ON. It will remain ON until normal battery volts are restored.
•
If the inverter shuts down due to not enough battery volts, then LED (3)
will flash.
•
LED (3) will continue to flash until the battery volts have risen
sufficiently. In this case, charge the battery by starting the vehicle or
using a battery charger.
The low voltage point that the inverter will cut out is adjustable to suit your
particular battery, see page 12 for details of this adjustment.
LED (4)
Temperature Overload
should normally remain OFF. If the inverter
shuts down due to internal components getting too hot, then this LED (4)
will come ON. It will remain ON until the temperature has lowered to a safe
level. The inverter will then come back ON.
•
If this LED (4) is coming on regularly, either reduce the amount of load
on the inverter or try to move the inverter to a cooler location.