8
Mode
Demand Start Adjust
Low Volts Adjust
Alarms
4 Watts
DC Volts Low/High
TEMP Overload
8 Watts
STATUS
AC Volts ON
AC Overload
12 Watts
16 Watts
DEMAND START
LED 1
LED 2
LED 3
LED 4
LED 5
Mode Button
Demand Start Wattage
LED 1
LED 2
LED 3
LED 4
4 Watts
ON
5 Watts
Slow flash
ON
6 Watts
Medium flash
ON
7 Watts
Fast flash
ON
8 Watts
ON
9 Watts
Slow flash
ON
10 Watts
Medium flash
ON
11 Watts
Fast flash
ON
12 Watts
ON
13 Watts
Slow flash
ON
14 Watts
Medium flash
ON
15 Watts
Fast flash
ON
16 Watts
ON
Continuous
ON
ON
ON
ON
After “continuous”, the next button press “rolls back” the demand start setting to 4 Watts
LOW VOLTS ADJUST - LED 5 (green) FLASHING
To avoid total discharging of your battery the WM1500 shuts down at a pre-set low voltage. As all
batteries are different, so too is the minimum voltage they should be discharged to. The WM1500 will
leave the factory with a setting of
22.0 Volts
, change this setting if required.
From Demand Start Adjust, page 6, hold the Mode button down, (approximately 1 second), until LED 5
is FLASHING, indicating you are ready to adjust this setting. Now press the Mode button until the
desired value is sought. LED’s 1 – 4 will return to Status Indication after 10 seconds if a key is not
pressed.
Low Volts Cut-out
LED 1
LED 2
LED 3
LED 4
20.0 Volts
ON
20.2 Volts
Slow flash
ON
20.4 Volts
Medium flash
ON
20.6 Volts
Fast flash
ON
20.8 Volts
Fastest flash
ON
21.0 Volts
ON
21.2 Volts
Slow flash
ON
21.4 Volts
Medium flash
ON
21.6 Volts
Fast flash
ON
21.8 Volts
Fastest flash
ON
22.0 Volts
ON
22.2 Volts
Slow flash
ON
22.4 Volts
Medium flash
ON
22.6 Volts
Fast flash
ON
22.8 Volts
Fastest flash
ON
23.0 Volts
ON