12
WM1500 ELECTRICAL SPECIFICATIONS
INVERTER TYPE
PWM Full Bridge power stage, with true sine wave AC output.
SELECTRONIC WM1500 INVERTER SPECIFICATIONS
ELECTRICAL
PARAMETER
WM1500
CONDITION
Output Power
@ 25 °C Ambient
1,500 watts
2,250 watts
4,500 watts
Max Continuous
1/2 Hour Rating
Max Surge
Output Power
@ 40 °C Ambient
1,400 watts
2,100 watts
4,500 watts
Max Continuous
1/2 Hour Rating
Max Surge
Voltage Input Range
20 - 34V DC
Range
Input Current
0.05A DC
0.6A DC
70A DC
210A DC
Stand By
Inverter ON – No Load
Max Continuous
Max Surge
Demand Start Sensitivity
Response Time
Factory Setting
4-16W
1 Second Max
4W
User Adjustable
Factory Setting
Low Voltage Shutdown
High Voltage Shutdown
Factory Setting
(Low Voltage Shutdown)
20 – 23.0V DC
34V DC
22.0V DC
User Adjustable
Fixed
Factory Setting
Output Voltage
240V AC +/- 4%
@ Nominal DC Input,
No Load to Full Load
Output Current
6.25A AC
18.75A AC
Max Continuous
Max Surge
Output Wave Shape
Output Frequency
Total Harmonic Distortion
True Sine Wave
50Hz +/- 0.01%
< 4%
Power Factor Limitations
Nil
Input / Output Isolation
1,875VAC
Memory Retention
Permanent
Operating Temperature Range -10 °C - 50 °C
Conforms to standards
AS 3100 (wiring), AS 3108, C tick
MECHANICAL
Size
410mm wide x 175mm high x 342mm deep
Weight
14kg
Weight Packed
17kg
Input Lead Length
1.5 metres
Output Wiring Method
Three terminal junction box with conduit knock outs
Chassis
Powder coated zinc steel (Wedgwood Blue)
DC Isolation
Single Pole Circuit Breaker
Warranty
5 year parts and labour (Conditions apply)
Notes:
The above specifications are based on unity power factor.
The DC Input is electrically isolated from the AC Output.
Through a policy of continued development, specifications are subject to change without notice