5
Verify that the circuit breaker on the front panel is in the OFF position, LEVER DOWN.
Now connect the battery cables.
RED
BATTERY POSITIVE (+)
BLACK
BATTERY NEGATIVE (-)
These connections should be tight. If using nuts, bolts and washers, they should be stainless steel. At
this point re-check the connections before proceeding any further.
WARNING:
IF THE WM1500 EMITS A VERY LOUD TONE, THE BATTERY LEADS HAVE BEEN CONNECTED IN
REVERSE POLARITY. IMMEDIATELY DISCONNECT THE LEADS AND RECONNECT WITH THE
CORRECT POLARITY. DO NOT, UNDER ANY CIRCUMSTANCES, TURN ON THE BREAKER WHEN THE
BUZZER IS SOUNDING, AS PERMANENT DAMAGE TO THE WM1500 WILL RESULT.
If all is well you can now switch the circuit breaker ON.
Mode
PROUDLY DESIGNED & MADE IN AUSTRALIA
Demand Start Adjust
Low Volts Adjust
Alarms
DC POWER
4 Watts
DC Volts Low/High
TEMP Overload
8 Watts
DC TO AC POWER
STATUS
AC Volts ON
AC Overload
12 Watts
16 Watts
Off
ON
DEMAND START
Front Panel
SERIAL
JUNCTION BOX
RATINGS LABEL
N E A
Base