Fault Finding
No indicators ON when power is first applied
When first connected, if the LD200 shows no indicators the battery
connections may be reversed. Check that the red battery wire (6) is connected
to the battery positive, and the black battery wire (7) is connected to the
battery negative.
Inverter shuts down during the middle of the day, and comes
back ON late in the afternoon
This is more than likely caused by high battery volts during peak charging
times from Solar Panels. Battery volts should never exceed 17 volts. If this is
the case, have your Solar Regulator checked.
LD200 Manual
Selectronic Australia
3
Portable Use
By connecting battery clips, the LD200 can be clipped directly to a vehicle
battery. When using battery clips ensure they have a tight grip around the
battery post. Wherever possible battery connections should be bolted. If
connecting the LD200 through a cigarette lighter socket the maximum
power output of the LD200 will be
severely
restricted, this practice should
be avoided. Check with your supplier or installer if you are unsure.
Do not use battery clips in a moving vehicle
Auxiliary Battery
Earth (to chassis)
LD200 Inverter
Start Battery
Earth (to chassis)
Isolator
Vehicle
Alternator
By incorporating an auxiliary battery in the manner above, the starting battery
should remain charged for vehicle starting (see your auto electrician).
The LD200 has sufficient battery cable length to allow it to sit underneath the
vehicle whilst in use. If the ground is wet, place the LD200 on a waterproof
liner.