Fault Finding 

No indicators ON when power is first applied 

When first connected, if the LD200 shows no indicators the battery 
connections may be reversed. Check that the red battery wire (6) is connected 
to the battery positive, and the black battery wire (7) is connected to the 
battery negative.  

Inverter shuts down during the middle of the day, and comes 
back ON late in the afternoon 

This is more than likely caused by high battery volts during peak charging 
times from Solar Panels. Battery volts should never exceed 17 volts. If this is 
the case, have your Solar Regulator checked. 

LD200 Manual 

Selectronic Australia

 

Portable Use 

By connecting battery clips, the LD200 can be clipped directly to a vehicle 
battery. When using battery clips ensure they have a tight grip around the 
battery post. Wherever possible battery connections should be bolted. If 
connecting the LD200 through a cigarette lighter socket the maximum 
power output of the LD200 will be 

severely

 restricted, this practice should 

be avoided. Check with your supplier or installer if you are unsure.

 

 
Do not use battery clips in a moving vehicle 

 

Auxiliary Battery

Earth (to chassis)

LD200 Inverter

Start Battery

Earth (to chassis)

Isolator

Vehicle
Alternator

 

By incorporating an auxiliary battery in the manner above, the starting battery 
should remain charged for vehicle starting (see your auto electrician). 
The LD200 has sufficient battery cable length to allow it to sit underneath the 
vehicle whilst in use. If the ground is wet, place the LD200 on a waterproof 
liner. 

 

Summary of Contents for LD200-12

Page 1: ...LECTRONIC A S LD200 12 Operating Manual Serial No _____________________________ Purchase Date ______________ Note Your 2 Year Warranty can only be valid once your warranty card is completed and returned to Selectronic Australia USTRALIA ELECTRONIC A S ...

Page 2: ...nd Pointers Examples LD200 Manual Selectronic Australia 13 Selectronic Authorised Service Network Selectronic Australia Suite 5 20 Fletcher Road Mooroolbark Victoria 3138 Australia Ph 61 3 9727 6600 Fax 61 3 9727 6601 service selectronic com au Burley TV Service Rainbow Power Company 278 Edmondson Ave 1 Alternative Way Austral Nimbin NSW 2171 NSW 2480 Australia Australia Ph 02 9606 0279 Ph 02 6689...

Page 3: ...C 10 Amp Single Pole Powder Coated Zinc Steel LD200 Manual Selectronic Australia 1 Introduction Thank you for choosing to purchase the Selectronic LD200 True Sine Wave Inverter Many hours of Research and Development have gone into the LD200 to ensure this inverter provides you with many years of reliable service Warranty Card It is imperative that you complete your warranty card NOW Your LD200 is ...

Page 4: ...inverter is as lethal as mains electricity LD200 Manual Selectronic Australia 11 Product Warranty Conditions Warranty Selectronic Australia Pty Ltd warrants your inverter to be free from defects in materials and workmanship under normal use and service for an initial period of two 2 years Defective parts will be replaced or repaired free of charge within this period Conditions This warranty is app...

Page 5: ...battery clips the LD200 can be clipped directly to a vehicle battery When using battery clips ensure they have a tight grip around the battery post Wherever possible battery connections should be bolted If connecting the LD200 through a cigarette lighter socket the maximum power output of the LD200 will be severely restricted this practice should be avoided Check with your supplier or installer if...

Page 6: ...24 Volts 100 Ah This would not suit your 12 Volt LD200 LD200 Manual Selectronic Australia 9 3 Once a fortnight or as directed in your battery manufacturer check the specific gravity SG of each battery cell using a hydrometer to ensure that all cells are performing correctly and are properly charged Any serious imbalance should be reported to your system designer in case remedial action needs to be...

Page 7: ...bank Unbolt the stainless steel bolts and nuts of any corroded connections and thoroughly clean the joint with a wire brush or file taking extreme care not to short circuit any battery cells with any tools Re assemble and smear a small amount of Vaseline or similar grease over the surface of the joint to slow down any future corrosion LD200 Manual Selectronic Australia 5 Where batteries are joined...

Page 8: ...tor LED s LED 1 ON Indicates that the inverter is supplying power to the load LED 2 DC Volts Low DC Volts High Flashing If the inverter shuts down due to low battery voltage the battery is flat then LED 2 will flash Charge the battery by starting the vehicle or use a battery charger When the battery is charged the battery voltage will rise LED 2 will turn OFF and the inverter re activate Permanent...

Reviews: