SP LINK | Using SP LINK
30
|
Doc #OI0005 Rev26 2020
AUTOMATIC RESETTING THE STATE OF CHARGE (SoC)
During the firmware update process SP LINK reads the SoC from the SP PRO.
When the SP PRO is restarted as part of the firmware update process, the SoC in the SP PRO is lost.
Reconnecting SP LINK after the firmware update is completed will initiate an automatic updated of the SoC
back to the SP PRO.
If the SP PRO is communicating with a Battery Management System (such as LG Chem) then the SoC is
automatically set by the BMS and this process does not occur.
AFTER UPDATING FIRMWARE
Connect SP LINK to the SP PRO.
For existing systems, load the saved Configuration file into SP LINK and make any required changes to your
configuration settings. Check the
String Inverter
setting as this may have changed during the firmware update
process (See String Inverter on page 59.)
For new system it is recommended that the Site Configuration Wizard be used now to configure the SP PRO.
For updates from a firmware version that is less than 7.00 to a version that is 7.00 or greater,
some settings will no longer be active and reprogramming Configuration Settings may be required.
For full details see the document “Migrating Legacy Settings” in the Help menu within SP LINK.
Program your previously saved configuration settings back into the SP PRO using the Configure SP PRO
button.
Summary of Contents for SP PRO 2i Series
Page 1: ...Instruction Manual for SP LINK Configuration and monitoring for SP PRO series 2i ...
Page 31: ...SP LINK Using SP LINK Doc OI0005 Rev26 2020 31 Blank Page ...
Page 91: ...SP LINK Performance Monitoring Doc OI0005 Rev26 2020 91 BLANK PAGE ...
Page 97: ...SP LINK Service Settings Doc OI0005 Rev26 2020 97 Blank Page ...