SP LINK | Configuration Settings
46
|
Doc #OI0005 Rev26 2020
The ON SoC NIGHT ASSIST
state of charge control
monitors the State of Charge through the highest usage
period, usually during the evening. If the battery level
has dropped to the
Start SoC
level at the appointed time
(between the
Start Time
and the
Stop Time
) the SP PRO
will start the generator and raise the state of charge until
the batteries reach the
Stop SoC
level. This prepares the
system for the night ahead.
ON SoC RENEWABLE PREFERRED is designed to
monitor the input from the solar array and, on a day when
the renewable sources may be low in output, on a cloudy
day or a day with no wind, start the generator at a lower
state of charge to ensure the batteries do not get too low.
This setting allows you to set a
Start SoC
percentage and a
Stop SoC
percentage that will keep the batteries in a “safe”
state of charge.
If the solar input does not meet the usual consumption level
you can start the day with a compensating charge that will
enable the normal solar input to fully charge the batteries.