SP LINK | Configuration Settings
62
|
Doc #OI0005 Rev26 2020
The Digital Control section is used to switch an output on or off with a digital
input. For example, if the input that is set in
Digital Control Input
setting (
Digital
Input 2 in the example) is activated then the output set in
Digital Control Output
will be controlled (Relay Output 4
in this example) The output can be reversed using
the
Output State
setting. In the given example a positive input to Digital Control
Input 2 from an upper float switch could switch off a water pump via Relay Output 4.
In short you can control many different types of appliances or warning devices from
digital inputs.
The switching of a digital input is recorded as events on the event log and can be
monitored by downloading data.
The SP PRO has two analogue inputs that can control the full range of output
options. The analogue input is set in
Analogue Control Input
. An analogue input
differs from a digital input in that instead of reacting to an on/off type signal as a
digital input does. An analogue input reacts to a pre-programmed upper and lower
voltage level which are set in
Input Assert Level
(on voltage point) and
Input De-
Assert Level
(off voltage point).
As an example if a suitable moisture sensor was connected to Analog Input 1 the
output from Relay Output 3 could be used to switch a watering system on and off
depending on the moisture content of the soil.
An Accredited Integrator can help you with specific applications that you may
require.
The Grid Fail Generator Backup
section controls the Solar Hybrid function allowing
for a Backup Generator to be automatically controlled during times of Grid failure.
These setting must be used in conjunction with an optional external controller
supplied by Selectronic. Full details of correct settings will be supplied with the
optional controller.
Summary of Contents for SP PRO 2i Series
Page 1: ...Instruction Manual for SP LINK Configuration and monitoring for SP PRO series 2i ...
Page 31: ...SP LINK Using SP LINK Doc OI0005 Rev26 2020 31 Blank Page ...
Page 91: ...SP LINK Performance Monitoring Doc OI0005 Rev26 2020 91 BLANK PAGE ...
Page 97: ...SP LINK Service Settings Doc OI0005 Rev26 2020 97 Blank Page ...