58
Selectronic Australia
Rev 41 - Dec 2022
Service
SP Pro Series Specifications
SPMC240
SPMC241
SPMC480
SPMC481
SPMC482
SPMC1201
SPLC1200
SPLC1202
Nominal battery voltage
24V
24V
48V
48V
48V
120V
120V
120V
Continuous (rated), output power
Rated apparent power
Continuous inverter AC current
Continuous, DC charge current
Continuous DC discharge current
3,000W
3,000VA
12.5A
125A
148A
4,500W
4,500VA
18.8A
188A
220A
3,500W
3,500VA
14.6A
73A
83A
5,000W
5,000VA
20.9A
104A
119A
7,500W
7,500VA
31.3A
156A
179A
7,500W
7,500VA
31.3A
63A
71A
15,000W
15,000VA
62.5A
125A
129A
20,000W
20,000VA
83.4A
167A
175A
Continuous grid export power
The SP PRO will not export active power to the grid, as per the requirements of AS/NZS 4777.2:2200 appendix M
Continuous output power
Continuous DC charge current
40°C
2,700W
113A
3,900W
163A
3,100W
65A
4,400W
92A
6,700W
140A
6,700W
56A
15,000W
125A
20,000W
167A
20 second Load rating
20 second output current
7,500W
28A
10,500W
40A
8,400W
33A
12,000W
47A
18,000W
70A
18,000W
70A
33,000W
135A
38,000W
155A
1 minute output power
5,400W
7,600W
6,000W
8,700W
13,000W
13,000W
26,000W
35,000W
30 minute output power
4,200W
6,750W
5,250W
7,000W
11,250W
11,250W
23,000W
30,000W
60 minute output power
3,200W
4,700W
3,700W
5,300W
8,000W
8,000W
18,000W
24,000W
DC input and output voltage range
20 – 32V
20 – 32V
40 – 64V
40 – 64V
40 – 64V
100 – 162V 100 – 162V
100 – 16V
Transfer Switch (Synchronous)
AC transfer current capacity
63A
125A
Max AC input source (generator / grid)
15 kVA
30 kVA
Max total output to Load, AC
inverter
15 kVA + Output Power of the SP PRO
30 kVA + Output Power
of the SP PRO
AC transfer time
no-break
If grid fails
0 – 0.03 seconds
Battery charger type
Temperature compensated, 5 stage, power factor corrected with dual stage Float
Efficiency
DC consumption idle
6W
ON with no Load
25W
33W
26W
35W
43W
43W
89W
90W
Peak efficiency – all modes
95%
95%
95%
95.5%
96%
96.5%
97.2%
97.2%
10% Load
90%
90.5%
90.5%
91%
91%
91.5%
93.3%
94.8%
20% Load
92.5%
93%
93%
94%
94%
94%
95.8%
96.8%
50% Load
94%
94.5%
94.5%
95%
95.5%
96%
97.2%
97.1%
100% Load
90%
91%
91.5%
92.5%
93%
93.5%
96.8%
95.5%
AC Output (standalone)
Range
210 to 240V + / -0.5%
Power Factor Range
0.1 to 1.0 leading or lagging
Maximum AC fault current (RMS)
35A
52A
41A
58A
86A
86A
175A
230A
Over current protection rating (external)
63 A
125 A
Output short circuit current
28A
40A
33A
47A
70A
70A
135A
155A
Decisive Voltage Class
C
Over Voltage Class
OVC III
Regulation
<1% droop 0–100% rated Load (<2% @ 150%, <5% @200%)
THD
<3% @ 0–200% rated Load
Frequency
50 or 60Hz + / -0.005% standalone
AC SOURCE (input)
Nominal Voltage
240 V~
Power Factor Range
0.1 to 1.0 leading or lagging
AC Current (all modes)
63 A
125 A
Tolerance on nominal voltage
Configurable 204 to 264 V~
Over current protection rating (installed
external to inverter)
Miniature circuit breaker (MCB) IEC 60947-2, trip curve C: Single-Pole, 63 A, 6kA fault
current interrupting capacity (Icu) at 240V
MCB IEC 60947-2,
trip curve C: Single-Pole, 125
A, 10 kA Icu at 240V
Rated short time withstand current (Icw)
6kA 1s
10kA 1s
Rated peak withstand current (Ipk)
6kA
10kA
Decisive Voltage Class
C
Over Voltage Class
OVC III
Nominal input frequency
50 / 60Hz
Tolerance on nominal frequency
Config / -1% to 10%
Active Anti-Islanding method
LF impedance measurement – Complies with IEC 62116:2014
Generator can be started by
Battery SoC, DC voltage, battery Load, unit temperature, time & remote control
Appendix A - Specifications