19
H
W
NOTE: It is of utmost importance that this chimney be
installed in accordance with these instructions. Certifica-
tion of the chimney is void if the installation instructions
are not followed. The CF Sentinel chimney requires 2"
(50mm) clearance (air space) to combustible material.
Refer to the following sections in these instructions to
complete your installation to a masonry fireplace:
- Pre-Installation Guidelines
- CF Sentinel Joint Security
- Framing Details
- Attic Insulation Shield
- Firestop Joist Shield
- Elbow Installation
- Roof Support
- Roof Flashing
- Roof Brace Kit
- Round Top
- Smoke Pipe Adaptor
Model CF Sentinel Anchor Plate provides a connection from a
masonry fireplace to a Selkirk Model CF Sentinel chimney. The
following steps describe the installation of this part (component)
and the above mentioned sections of these instructions are to be
followed.
1. Mount four (4) 1/4" diameter bolts, 3" long securely into the
top of the masonry fireplace around the outlet opening. Use the
4 holes on the anchor plate as a template to locate the placement
of these bolts.
2. Apply a bed of mortar approximately 3/4" in depth and 3" in
width completely around the fireplace opening. Make sure the
threaded ends of the bolts protrude a minimum of 1" above the bed
of mortar.
3. While the mortar is still damp, place and level the Anchor Plate
over the extended studs. Secure using a washer and nut for each
bolt.
4. Check the Anchor Plate for level and allow mortar to set.
5. Place the flue extension (crimped end down) into the opening
of the Anchor Plate. Place a section of chimney onto the Anchor
Plate and secure to the Anchor Plate with a Locking Band and
stainless steel sheet metal screws (see CF Sentinel Joint
Security section of these instructions and Figure 4). Up to 85 feet
of chimney may be stacked on the Anchor Plate.
ANCHOR PLATE - MASONRY FIREPLACE
All Masonry or Steel Shell
Model Sentinel CF
Chimney Lenght - Requires
2" (50mm) clearance to
Combustibles
Attic Insulation Shield
Flashing
Storm collar
Round Top
"LISTED" FACTORY-BUILT FIREPLACES
When Selkirk chimney Model CF Sentinel is approved with a
"Listed" factory-built fireplace, the chimney and fireplace are
tested in combination as a complete system and the fireplace
instructions must be followed.
Where required in the "Listed" factory-built fireplace installation
instructions, an Anchor Plate can be used to provide a connection
from a "Listed" factory-built fireplace to the insulated chimney
Model CF Sentinel.
Anchor Plate Assembly
Ensure that you obtain any necessary building permits and that your installation will conform with all federal, provincial,
municipal installations and fire codes for all requirements affecting your installation. Check with your local Building Code
for masonry fireplace requirements.