Summary of Contents for SL-7510 Series

Page 1: ...www selletonscales com SL 7510 SERIES INDICATOR USER S MANUAL SL 7510 E SL 7510 C Series 9 9 19...

Page 2: ...3 Power Supply 4 Displays 5 Display and Key Descriptions 6 Operating Instructions 7 9 Calibration 10 Indicator Parameter Settings 12 16 Helpful Definitions 17 Connectors 18 19 RS232 Serial Output For...

Page 3: ...e sure the weight is not over the Max capacity as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the s...

Page 4: ...optional Rechargeable battery optional Indicator Model Options The SL 7510 series consists of the SL 7510 E LED series and SL 7510 C LCD series Options for rechargeable battery stainless steel enclosu...

Page 5: ...3 SPECIFICATIONS FIGURE 1 INDICATOR MEASUREMENTS...

Page 6: ...icator Please use only the AC adapter provided to prevent dam age to your indicator To keep the battery in best condition fully discharge the battery every month by leaving the indicator on until the...

Page 7: ...5 SL 7510 E LED SL 7510 C LCD...

Page 8: ...e to see the gross weight pallet product ZERO Zero s the scale PRINT Print data The scale is at zero The scale is stable Gross Shows you are in Gross weight mode includes tare default mode Net Shows y...

Page 9: ...lb oz lb oz press the UNITS key Tare Function The Tare function is used when you only wish to see the current change in weight not the entire amount of weight that is on the scale When the indicator...

Page 10: ...stabilize the scale Add the second weight to the scale Once stable press the ACCUM key to add the weight to the accumulated total The screen will show n002 to indicate the second weight has been saved...

Page 11: ...stable the indicator will hold that weight on the screen for 3 seconds then go back to general weighing Pressing the hold key is unnecessary holding is done automatically when the scale is stable 4 Av...

Page 12: ...14 Enter in the maximum capacity you want to use for this scale by using UNIT and COUNT to move the cursor left and right and TARE and ZERO to move the values down and up The C4 channel is used to ent...

Page 13: ...ss PRINT to access the C06 channel The display will show C6 0 3 The C6 channel is used to calibrate the scale with a known weight Press ZERO to set the value of C6 to C6 2 Press PRINT The display will...

Page 14: ...ate through the settings C01 to C45 as shown in the table 4 below by using the arrow keys and return keys as labeled under each indicator button 4 Press the PRINT key to enter edit the parameter setti...

Page 15: ...y holds data when stable 4 Average hold for animal weighing averages the weight from a sample of 3 seconds 5 Auto Average hold Average hold without the need to press the hold key Unit Conversion C12 S...

Page 16: ...r than manual zero range Zero Tracking Time C23 0 turn off zero tracking time 1 1 second 2 2 seconds 3 3 seconds Overload Range C24 00 turn off overload range 01 99d overload range setting d division...

Page 17: ...9 7000 9 9999 Version No C38 Print Mode C41 0 auto mode 1 gross mode 2 tare mode Print Carriage Return C42 0 9 How much space between print outs Space Print C43 0 9 Where the data prints on the paper...

Page 18: ...Alarm C14 000000 Inner Code Display C15 Set Date C16 Set Time C17 Communication Setting C18 0 Baud Rate C19 3 9600 Manual Zero Range C20 10 Initial Zero Range C21 10 Zero Tracking C22 0 5 Zero Trackin...

Page 19: ...the time allowed for the scale to fall within the zero tracking range tolerance and still qualify to be zero d Overload Range Weight allowance that is out of the set calibrated range Adds a tolerance...

Page 20: ...dicator Quick Disconnect as shown below FIGURE 2 QUICK DISCONNECT CONNECTION DIAGRAM Hardwire Using Inner Terminal Block Connection Note Make sure you follow all the anti static rules to avoid damage...

Page 21: ...ITE Negative output signal from load cell EXC EX BLACK Negative excitation voltage to load cell DB9 Connection 9 pin Serial Connector The DB9 9 pin serial connector is used for different purposes depe...

Page 22: ...rial parameters 8 data bits 1 stop bits No parity No handshaking Note With the RS232 Output option we have data logging software available as seen in Figure 5 FIGURE 5 DATA LOGGING SOFTWARE Below are...

Page 23: ...0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 State B BitsS function Bits0 gross 0 net 1 Bits1 Symbol positive 0 neg...

Page 24: ...Mode C18 3 In this mode the indicator can recieve ASCII commands as listed below Command Name Function T Tare Save and clear tare Z Zero Zero gross weight P Print Print the weight R G W N W Read gros...

Page 25: ...C18 5 STX POL XXXXX XX L K G N STAT CR LF Start Transmission Polarity SP Positive Negative Weight Data Units lb punt kg kilogram pcs pieces Gross Net GR Gross NT Net Carriage Return Line Feed Status...

Page 26: ...connect your scales 4 20 mA output to a data acquisition device Below is a list of important notes when using the indicator with the 4 20 mA option Resolution 1 1000 Outside Load 100 350ohms Inside c...

Page 27: ...signal Out3 Turn on under load control function Output under load control signal Out4 Turn on stable control function Output stable control signal C33 2 3 Preserved no function Table 7 below shows th...

Page 28: ...See Q A section ERR1 During calibration weight is not used or the weight is above the max capacity Use correct weight within the defined range ERR2 During calibration the weight is below the minimum r...

Page 29: ...key If 100 is not available change to 20 7 Press PRINT key to enter your selection 8 The screen will read C21 now 9 Press PRINT key to enter C21 parameter 10 Change the value on the right of C21 to 1...

Page 30: ...CONTACT US Please e mail info selletonscales com for any sales related questions or call 844 735 5386 Don t forget to visit our website at www selletonscales com...