background image

 

DT-E 1.1: SUN PROTECTION SCREEN – VENETIAN BLINDS C50 Slim                                                                                                                                                                           
Issue 2 / April 2017 / EN                                                                                                                                                                                

 

        page  16 / 25                                                                                                                                                      

 

 

 

 

 

           

When the product starts working attention should be paid to: 

 

correct opening and closing of the product  

 

correct activation of limit switches 

 

 

Incorrect connection of the motor can lead to product damage or create a hazardous situation. 

 

 

The engine has a thermal switch, which turns off the drive after about 4 minutes of continuous work to 
protect against overheating. After turning off by the thermal protection appropriate time should pass 
before  turning  on  again,  depending  on  the  type  of  engine  and  ambient  temperature  (about  16 
minutes). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Venetian Blind C50 Slim

Page 1: ...1 Sun protection screen Venetian Blind 1 1 Venetian Blind C50 Slim TECHNICAL AND OPERATIONAL DOCUMENTATION INSTALLATION AND OPERATING MANUAL AND INSTRUCTIONS FOR SAFE USE 1 1 DT E DTE DT E...

Page 2: ...e ul Wschodnia 23A POLAND Plant address Fa ade and External Textile Roller Blind Department 45 449 Opole ul Wschodnia 23A POLAND Contact details Tel 48 77 553 21 00 secretariat Fax 48 77 553 22 00 Web...

Page 3: ...hanging system 10 4 5 2 C50 Slim installation cable guides 12 4 5 3 C50 Slim installation manual drive 15 4 6 Electric drive 15 4 6 1 Connection to power supply 15 4 6 2 Start up and adjustment 15 5...

Page 4: ...as ammended Linked documents Declaration of conformity and manual of installation and use of motors and control 1 2 NOTES ON SYMBOLS AND MARKS The below symbols icons denote particularly important in...

Page 5: ...user IMPORTANT INFORMATION REGARDING SAFETY WARNING FOLLOWING THE MANUAL IS ESSENTIAL FOR SAFETY OF PEOPLE KEEP THIS MANUAL The documentation is valid jointly with the information concerning a specifi...

Page 6: ...he following parameters supply voltage 230V 50Hz power 90 to 115 W depending on the motor type and blind size current consumption 0 4 to 0 5 A depending on the motor type and blind size protection lev...

Page 7: ...s during their work emission of noise through a product with electronic drive connected with work of mechanical parts caused by electric drive during its work is not said regarded to be a significant...

Page 8: ...the package which in turn can lead to permanent damage of the product Products placed on the means of transport must be secured against movement and damage during transport e g spacers safety belts et...

Page 9: ...ty elements have to be installed and adjusted according to the included Information on safety elements installation 4 1 REQUIREMENTS FOR SAFE INSTALLATION AT HEIGHTS Installation of the product due to...

Page 10: ...chemical substances containing bituminous substances or any other substances making reactions with the product is forbidden Improper installation may cause hazardous situation for the user 4 4 INSTAL...

Page 11: ...BLINDS C50 Slim Issue 2 April 2017 EN page 11 25 Img 2 2 Drill holes for fixing system Img 3 Img 3 3 Fix the first bracket to the wall ceiling so that further adjustment is possible Img 4 4 Fix secon...

Page 12: ...Correct if necessary Img 6 Img 6 6 Install head rail with bundle in the brackets Img 7 and close the brackets Img 8 Img 7 7 Close the bracket Img 8 4 5 2 C50 SLIM INSTALLATION CABLE GUIDES Follow firs...

Page 13: ...pril 2017 EN page 13 25 2 Install head rail with bundle in the brackets Img 2 and close the brackets Img 3 Img 2 3 Close the bracket Img 3 4 With spirit level mark installation spot for angular cable...

Page 14: ...uides in bushes Check the vertical level on guides If correction is necessary change the position of bush in the bracket appropriately Cut of the cable excess Img 9 1 Check if brackets are installed s...

Page 15: ...ual of motor manufacturer Manuals are added to the product as well as are available on motor manufacturer s website and www selt com PRODUCTS AUTOMATION Environmental conditions of increased threat ba...

Page 16: ...of limit switches Incorrect connection of the motor can lead to product damage or create a hazardous situation The engine has a thermal switch which turns off the drive after about 4 minutes of contin...

Page 17: ...carefully The switch should be mounted at the height conforming to the national regulations concerning disabled persons not lower than 130cm at best For products with manual drive cords added cord br...

Page 18: ...the system is working It is forbidden to use a product while not conforming to the electric shock and fire safety requirements It is forbidden to exceed specific work parameters of the product determ...

Page 19: ...tely or consciously by the user applying admissible values of work parameters observing abiding recommendations for use carrying out periodic product inspections and maintenance following the requirem...

Page 20: ...peration Routine maintenance activities should be carried out on a maximally opened system Basic product maintenance activities are checking if the venetian blind unfolds and folds properly checking i...

Page 21: ...and lubrication Electrical devices delivered to the Supplier in a manner not allowing for operation check e g cut off motor cable receiver in parts Damages of electrical origin as a result of user fa...

Page 22: ...detailed description of the defect the name of the company which assembled the product and the date of finding out the defect Product with no invoice number order or contract number will be considere...

Page 23: ...se effect on the environment and human health No Subject European legal basis Polish legal basis 1 Waste electrical and electronic equipment Directive 2012 19 EU of the European Parliament and of the...

Page 24: ...ul Wschodnia 23A POLAND 13 2006 42 EC Cord version On the packaging a warning sticker with image according to EN 13120 standard is placed see point 11 of the documentation On packaging of safety eleme...

Page 25: ...in security grip Cord ending INSTALLATION MANUAL Endings of operation cords were finished with PVC elements cord endings to prevent the cords from twisting and creating a loop WARNING Young children c...