background image

SELVAS Healthcare, Inc. 

 

14

_ABOUT BODY COMPOSITION 

 

Abdominal Fatness 

Body fat is divided into subcutaneous fat and visceral fat. Visceral obesity is considered to be a critical risk 
factor along with Percent of body fat. 

Lipoprotein lipase can be easily activated in visceral fat, and it cause visceral fat to be dissolved easily. 
Dissolved visceral fat goes into liver through the vessel and it cause fatty liver or increasing lipid in the 
blood. It also elevates the risk of hyperinsulinemia, hypertension, and cardiovascular disease. 

Visceral  fat  generally  occupies  10  ~  20  %  of  body  fat,  and  visceral  obesity  is  assessed  based  on  the 
indicators below. 

 

the cross sectional fat area between L4 ~ L5 is 100 cm

2

 and over 

 

the visceral fat to subcutaneous fat ratio is 0.4 and over 

 

the waist to hip ratio (W.H.R.) is over 0.9 (male) / 0.85 (female) 

 

the circumference of waist is over 102 cm (male) / 88 cm (female) 

Visceral fat increases after their 30s in men and after Menopause in women. It is more common in men 
than women and the old than the young. Visceral fat tends to increase with aging. Because the combustion 
rate per minute of visceral fat is higher than that of subcutaneous fat, visceral fat can be easily reduced 
by exercise or dietary control in case of abdominal obesity. W.H.R. is the ratio of waist to hip circumference 
and has relation to one

s figure. 

Segmental Analysis 

This device analyzes soft lean mass of five body parts; trunk, right arm, left arm, right leg, and left leg. 
This function can be used as an assessment tool to evaluate the result of exercise or rehabilitation treatment. 

Age Matched of Body 

It is the estimated physical age of the subject considering body composition analysis result, gender, and 
biological age. This is calculated by comparing the optimal body composition based on the gender and 
biological age of the subject with the actual analyzed body composition. It can be used to evaluate the 
subject

s health and body development. 

 

 

Summary of Contents for ACCUNIQ BC300

Page 1: ...English 06 2021 V3 01 User Manual BC300...

Page 2: ...ice Directive 93 42 EEC THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93 42 EEC SELVAS Healthcare Inc 155 Sinseong ro Yuseong gu Daejeon 34109 Republic of Korea TEL 82 42 879...

Page 3: ...9 Basic Package 20 Options 21 INSTALLATION 23 Installation of product 23 Power Supply 25 Peripheral Device Installation 26 Connecting Computer 26 Connecting Printer 26 Connecting Blood Pressure Monito...

Page 4: ...re Program 51 STORAGE OF DATA USING USB MEMORY 53 Storage of data 53 Select of FLASH MEMORY 53 Select of USB MEMORY 53 ID Search Only with FLASH MEMORY 54 Data Deletion Only with FLASH MEMORY 54 Data...

Page 5: ...minal analysis AMB segmental analysis control guide etc Intended application location is professional healthcare facility environments not home healthcare environment WORD DEFINITIONS To ensure safe o...

Page 6: ...ssion Level B for Noise immunity by standard of IEC 60601 1 2 2014 Electromagnetic Compatibility Requirements SAFETY PRECAUTIONS This device is designed and manufactured with consideration of safety o...

Page 7: ...ent Configurations shall comply with the system standard IEC 60601 1 2005 A1 2012 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system...

Page 8: ...ving device Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or fi...

Page 9: ...our physician promptly Defective unit or accessories must be packed in the replacement cartons to be shipped off from you to our company Shipping and insurance costs for return of defective unit must...

Page 10: ...r their useful lives Alternatively the device shall be disposed in accordance with national laws after their useful lives ON OFF key Turn the power ON OFF Class II equipment This symbol is used inside...

Page 11: ...declaration electromagnetic emissions The ACCUNIQ BC300 is intended for use in the electromagnetic environment specified IEC 60601 1 2 2014 Fourth Edition 2 Guidance and manufacturer s declaration ele...

Page 12: ...SELVAS Healthcare Inc 12_INTRODUCTION The ACCUNIQ BC300 is intended for use in the electromagnetic environment specified IEC 60601 1 2 2014 Fourth Edition...

Page 13: ...the key factor in obesity assessment is the amount of fat accumulated in the body In general obesity is defined as the state of not only excessive weight compared with height visible obese but also ex...

Page 14: ...e 88 cm female Visceral fat increases after their 30s in men and after Menopause in women It is more common in men than women and the old than the young Visceral fat tends to increase with aging Becau...

Page 15: ...e Electrode Handle Electrode measure the impedance by sending harmless electric current to the body Hold them with the hands during measurement Key pad Key pad consist of numeric buttons from 0 to 9 a...

Page 16: ...er Adapter port ADAPTER Connecting an adapter Power switch It can be used to turn on off the power ZIGBEE port In case of using wireless communication with computer it can be used to connect ZIGBEE Wi...

Page 17: ...ing handle When transport is necessary the column can be folded down by turning the screw counterclockwise During this process hold the column with one hand and turn the screw with another hand Weight...

Page 18: ...er input of personal data Note Head part is connected to main body by limited length curl cord It allows measuring people in 100 200 cm height After the measurement return the head to the original pos...

Page 19: ...elect gender male or female button You can print out the result sheet Number 1 9 alphabet button You can input ID using this button ex If you want to input number 1 press button 4times 1 A B C Button...

Page 20: ...roduct is composed of Main body User guide Body composition management program CD A4 Result Sheet USB cable Power cable and adapter Main body User guide Program CD A4 Result Sheet USB cable Power cabl...

Page 21: ...measurer can easily check his her blood pressure Especially the patient with the hypertension can manage his her blood pressure efficiently through body weight control 2 Thermal Printer Thermal printe...

Page 22: ...T 5 Height Meter This is an instrument to measure subject s height more accurately and quickly It employs standoff determination method using ultrasonic sensor Refer to INSTALLATION MANUAL Caution Opt...

Page 23: ...ALLATION Installation of product 1 Unscrew all screws from the carry bag with screwdriver attached on the top of the bag 2 TOP mark should be indicated on top of the box when you place the carry bag U...

Page 24: ...picture Hold the device with both hands and take the device out 4 Place the device on the flat floor Stand the body part of device with one hand and fix the locking handle by turning it clockwise wit...

Page 25: ...peripheral device to this device the power should be turned off Otherwise this device can malfunction or be damaged due to electric shock 2 Power should be supplied from this device to ensure the safe...

Page 26: ...onnect the USB B port placed on the rear panel of this device to the USB port in computer with USB cable Connecting Printer 1 Connecting the device and the printer directly Connect A4 printer offered...

Page 27: ...les Connect the printer to the computer with printer cable The result sheet can be printed out from the printer Connecting Blood Pressure Monitor This device is connectable with automatic blood pressu...

Page 28: ...counterclockwise and open the cover as shown in the picture 2 Insert the thermal paper to the direction as shown in the picture 3 Slightly insert the edge of thermal paper to the printer slot Thermal...

Page 29: ...ction Press button 5 times at initial screen Press button to print the thermal paper CUT Function Press button 5 times at initial screen Press button to cut the thermal paper Note Do not pull thermal...

Page 30: ...r improvement Entering SYSTEM SETUP At the initial screen press 1 2 3 4 button in key pad to enter SYSTEM SETUP screen Menu in SYSTEM SETUP Menu items are displayed The function of each icon is as fol...

Page 31: ...P Select the menu by pressing and button Press BACK button in key pad BACK button act as SET button in SYSTEM SETUP and NEXT button act as CLOSE button Exiting SYSTEM SETUP Press NEXT button on SYSTEM...

Page 32: ...he same way 3 DAY 4 HOUR 5 MIN Press BACK button in key pad to save date and time Return to SYSTEM SETUP screen by pressing NEXT button in key pad Note 1 If BACK button is pressed before finishing set...

Page 33: ...Adjust volume with and button in key pad Press BACK button in key pad to save selected value Return to SYSTEM SETUP screen by pressing NEXT button in key pad PRINT It selects the printing mode of the...

Page 34: ...ssing button moves print position down or right Pressing button moves print position up or left Every single press moves print position by about 0 2 mm Press BACK button in key pad to save it Return t...

Page 35: ...body composition analysis as subject s weight Select CLOTHES on SYSTEM SETUP screen with and button and press BACK button in key pad Pre set 0 0 kg 0 0 lb Range 0 3 0 kg 0 7 27 lb Set the value with a...

Page 36: ...ominal analysis won t be displayed to the person below 18 years old Press BACK button in key pad to save it Return to SYSTEM SETUP screen by pressing NEXT button in key pad DATE TYPE It is to set a di...

Page 37: ...button in key pad Press BACK button in key pad to save it Return to SYSTEM SETUP screen by pressing NEXT button in key pad Communication Select the connecting method between ACCUNIQ BC300 and a comput...

Page 38: ...RY or USB MEMORY with and button in key pad If you use ID ID can be entered in 20 digits and saved in FLASH memory or USB memory Press BACK button in key pad to save it Return to SYSTEM SETUP screen b...

Page 39: ...he number of storage is different depending on the capacity of USB MEMORY b The result sheet can be printed only from thermal printer 3 The user should use USB memory option supplied only from our fac...

Page 40: ...UP screen by pressing NEXT button in key pad When GUIDE is set with YES guide screen will be displayed to help the user It showed up when the head part is lifted up after measuring weight When set wit...

Page 41: ...sult sheet in case of under 18 AUTO It automatically selects and prints a CHILD result sheet in case of under 18 and an ADULT result sheet in case of 18 or over 18 HEIGHT METER Adjust the height meter...

Page 42: ...er is not connected Height meter is not connected move to height input mode message will be appeared Check the cable which connects the height meter to the device If message above appears while height...

Page 43: ...ments from sitting to standing position etc Body fluid moves to the lower extremities and affects the results Thus subjects should be measured after maintaining a standing position for 5 minutes 6 Cle...

Page 44: ...stockings and then stand on the plate electrodes Remove sweat or foreign matters on the soles Fairly place the bare feet on the plate electrodes Make sure that the clothes are not between the soles a...

Page 45: ...orrect Posture Step the scale in the bare feet Stretch both arms and spread them 30 from the body Press start buttons with thumbs for 2 3 seconds to start the measurement Once it starts release the st...

Page 46: ...ubject should be input in the program first The saved information will be transferred to the device Basic Analysis 1 Weight measurement When the subject stands up on the scale the screen changes with...

Page 47: ...D and press button The data of Height Gender and age saved in ID automatically appears on the display The saved data can be changed by pressing button 2 When transmit the member information from Manag...

Page 48: ...data input press NEXT button in key pad ID usage NO Input height Input your height appears Input the subject s height with number buttons in key pad Press NEXT button Age input Input your age appears...

Page 49: ...subject s personal data the screen changes as shown in the picture Fit feet on plate electrodes accurately 2 Measurement posture 2 Stretch both arms and spread them 30 from the body 3 Measurement pos...

Page 50: ...ot complete due to the continuous errors Step down from the scale for the initialization Refer to ERROR REPAIR part for the detail Result screen After analysis is completed the result is displayed on...

Page 51: ...rogram CD for the detail Analysis Using Blood Pressure Monitor Software Program The blood pressure monitor from SELVAS Healthcare Inc can be connected to the device as an option In this way the blood...

Page 52: ...e computer screen after the completion of body composition analysis 8 Save the data or print it out Note 1 Blood pressure should be measured before body composition analysis Refer to the user manual o...

Page 53: ...lowing message appears Do you want to write data to USB memory stick on initial screen Press YES to send to USB memory 3 Transmitting message will be displayed on the screen When transmission is compl...

Page 54: ...o saved data will appear Please insert USB memory after measuring body composition 3 When the saving format is changed from USB MEMORY to FLASH MEMORY the data saved in USB MEMORY should be transferre...

Page 55: ...e using FLASH MEMORY error message appears as shown in the picture In this case please turn off and on the power and insert USB on initial screen Press 7777 in keypad Note There s a basic backup memor...

Page 56: ...ubtracting mass of body fat from body weight Lean body mass consists of fat free mass of body such as muscle organs blood and water 4 S L M Soft Lean Mass It composes of body water and protein 5 Miner...

Page 57: ...Body weight Waist to hip ratio W H R shows the distribution of fat stored in one s abdomen and hip It is simple but useful to assess fat distribution Body fat is stored in two distinct ways They are o...

Page 58: ...ity Level 7 A M B Age Matched of Body It is the estimated physical age of the subject considering body composition analysis result gender and biological age This is calculated by comparing the optimal...

Page 59: ...ntrol method Control guide and calorie prescription are proposed value for one s body type 12 Body composition change Check to change of weight body fat and muscle from previous and present measuremen...

Page 60: ...are in good condition 9 Do not splash any fluid on this device or insert any foreign substances 10 In case of inserting foreign substances or exposing to particular environment this device must be exa...

Page 61: ...e and alcohol Then wipe the enclosure with a soft lint Please wipe after every measurement for electrode disinfection 17 Refer to SAFETY PRECAUTIONS Caution Users must wipe with safety equipments such...

Page 62: ...out of range Clean the Handle electrodes and try again If the same error is repeated please contact our company or its local distributor where this device is purchased Out of range of measurem ent Wh...

Page 63: ...e electrodes with soft gauze and try again Clean hands and soles and try again Make sure there are no foreign substances between electrodes and measuring body parts It does not work even when start bu...

Page 64: ...formation which will assist your appropriately qualified technical personnel to repair those parts of unit which are designated by our company as repairable How to contact our company Write us at SELV...

Page 65: ...TER SERVICE_65 2 Turn off the power of the peripheral devices and disconnect all cables 3 Disassemble the device in reverse order of assembly 4 Pack the device with the original packing materials 5 Tr...

Page 66: ...control Fat control Impedance Segmental Frequency Blood pressure when connected with blood pressure monitor of our company QR code Result for Child and Youth optional Body Composition Analysis Weight...

Page 67: ...easuring weight 10 200 kg Applicable age 1 99 years old Operation ambient Ambient temperature range 5 to 40 C Relative humidity range 15 to 93 non condensing Storage ambient Ambient temperature range...

Page 68: ...Period of warranty Within 1 year from the date of manufacture Date of purchase Customer Add Name Tel Dealer market Add Name Tel Note When you receive this warranty make sure that the name of the deal...

Page 69: ...ck Mainframe 1 Keys Smooth operation Pass Fail 2 Recorder Smooth operation with no abnormal sound Pass Fail 3 Touch Screen Smooth operation Pass Fail Accessories 1 Power cord Smooth operation and remo...

Page 70: ...rame 1 Touch Screen Smooth operation Pass Fail 2 Recorder Smooth operation with no abnormal sound Pass Fail Accessories 1 Power cord Smooth operation and removal Pass Fail Electrical Check Performance...

Page 71: ......

Page 72: ...Stanislawa aryna 7c 02 593 Warszawa POLAND Tel 48 505 522 888 If the problems continue call the service center When you ask for service the manufacturer s label serial number date of original purchas...

Reviews: