10
4) Group separation
A group is an arrangement of several SELVE-Electronic-
Radio-motor controlled via one transmission channel.
The group is divided by initiating group separation.
During the group separation, every SELVE-Electronic-Radio-
motor moves randomly once only for 3 seconds within
approx. 2 minutes. If it is stopped using any transmitter, this
is learnt into the SELVE-Electronic-Radio-motor.
N.B.
Ensure that when a permanently installed switch is connected,
it is not in the UP or DOWN position.
In order to separate the group, proceed as follows:
disconnect from the power supply
The SELVE-Electronic-Radio-motor acknowledges the power
supply has been disconnected by moving slightly.
First press the STOP button on a
transmitter learnt in and then the UP
and DOWN buttons. Keep all three
buttons depressed for 9 seconds.
(Wait until the transmission control
light flashes three times.)
The SELVE electronic radio drive
acknowledges group separation has
been activated by moving slightly for
3 seconds.
Important:
This transmitter is deleted after the group
separation is completed.
Stop the movement within 3 seconds using the STOP button
of the transmitter to be programmed in.
Then the transmitter has been learnt in and the SELVE-
Electronic-Radio-motor is no longer in group separation mode.
If the SELVE-Electronic-Radio-motors still move as a group,
repeat the process for the relevant SELVE-Electronic-Radio-
motors with the transmitter that has been learnt into them.
N.B.
Group separation is ended either by using a control command
from a transmitter that has been learnt in or when the new
transmitter has been learnt in.
5) Adjusting the end limit using the allocated transmitter
disconnect from the power supply
The SELVE-Electronic-Radio-motor acknowledges „Powerdis-
connection“ by moving slightly.
When the STOP button of an allocated transmitter
is pressed for 6 seconds, the SELVE-Electronic-
Radio-motor can be switched to setting mode.
(Wait until the transmission control light flashes
twice).
It remains in setting mode until the lower and upper end limits
have been programmed.
The end limits are reset as described in
1.1.
Allocation of transmitters is not affected.
After the end positions have been set, the radio drive returns
to its normal operating mode.
1.
9 sec.
2.
3 sec.
SELVE-Adjustment instruction
6 sec.
disconnect from
the power supply
for 3 secs.
connect to the
power supply
for 3 secs.
disconnect from
the power supply
for 3 secs.
connect to the
power supply
disconnect from
the power supply
for 3 secs.
connect to the
power supply
for 3 secs.
disconnect from
the power supply
for 3 secs.
connect to the
power supply
GB