proper level. The proper level is to bottom of plug. DO NOT
OVERFILL.
o
Lubricate spur gears.
o
Apply lubricant directly to teeth of both spur gears liberally. (Use
heavy duty open gear lube.)
o
Replace all guards.
Annual lubrication: (After 2080 hours of operation).
o
Repeat steps from monthly lubrication.
o
Drain oil from reducer by removing plug “D” (see fig. 3, page 21).
o
Clean magnetic drain plug.
o
If excessive metal filings are detected on the magnetic drain plug,
flush reducer with cleaning solvent (kerosene).
o
Replace drain plug and refill to proper level using a high grade
petroleum base, rust and oxidation inhibited gear oil SAE 40W.
(AMOCO Industrial Oil No. 150 or equivalent.)
CAUTION:
Too much oil will cause over heating, and too little oil will result in gear
failure. Check oil level monthly. Also, under extreme operating
conditions, such as rapid rise or fall of temperatures, dust, dirt,
chemical particles, chemical fumes, or oil temperatures above 200
degrees F., the oil should be changed every one to three months
depending on the severity of conditions.
CONVEYOR BELT ADJUSTMENT
Alignment and Tensioning
o
Read all safety warnings (see page 8) before proceeding.
o
Lock power off.
o
Remove both end guards and side guards from input conveyor
o
Replace end guards
14
Summary of Contents for 800-1000 Series
Page 19: ...Figure 1 SHREDDER OPERATION 19 ...
Page 20: ...Figure 2 CHAIN LUBRICATION 20 ...
Page 21: ...Figure 3 REDUCER LUBRICATION PN TA5215H40 21 ...
Page 22: ...Figure 4 CONVEYOR BELT TAKE UP 22 ...
Page 23: ...Figure 5 CHAIN SAG 23 ...
Page 25: ...Figure 7 DRIVE BELT ADJUSTMENT 25 ...
Page 35: ......